2. General advice
Don‘t let the DZP 20-Z unattended during dispensing and remove possible pollutions according to
local regulations to prevent accidents.
3. Technical data
The liquids compatible with auto shott off digital nozzle must be a low viscosity bamely as below
Use of other fluids may be inaccurate and can damage the nozzle
Not suitable when used in a retail sale of diesel, oil or kerosene !
4. Description
LCD-Display
The LCD of the meter features two numerival registers and various indications displayed to the user
only when the applicable function so requires.
Key
①
Partial register (5 figures with moving comma from 0.1 to 99999) indicating the volume
dispensed since the reset button was last pressed
②
Indication of battery charge
③
Indication of calibration mode
④
Indication of resetting present total to zero
⑤
Total register
⑥
Indication of flow rate mode
⑦
Indication of unit of measurement of partial :
L = Litres
GAL = Gallons
PT = Pints
QT = Quarts
User buttons
The turbine digital meter features two buttons (MENU and RESET) wich individually perfprm two
main functions and together, other secondary functions.
The main functions perfomed are:
For the reset key, resettung the partial register and reset table total (reset total)
For the menu kea, entering instrument calibration mode.
used together , the two keys permit entering configuration mode.
Battery replacement
When replacing the battery, please open the cover, remove the plug and replace the battery.
5. Assembling / Installation
1 Connect the nozzle directly with the delivery hose. Please be ensure the thread is sealed.
2 Turn on the dispenser, open the trigger of nozzle to start dispensing. For first time using, it is necessary
to turn the trigger on and off 2-3 times to discharge the air inside.
3 After dispensing, turn off the nozzle and take back to the nozzle holder.
Modell no.
DZP 20-Z
Accuracy
5-Digit present total (0,01 ~ 999,99)
Flow rate
up to 60 LPM / 16 GPM
Fluid type
Diesel & kerosene
Units
Einheit (Liter, Gallonen, Pint, Quarts)
Screen
7-Digit non-resettable total (1~9999999)
Pressure (max) 50psi/3,5bar
Inlet and outlet
3/4"
Tolerance
±1%
Weight
1,3kg
Temperature
-10°C bis +50°C
Power supply
2xAAA
+49 (6158) 92980-0