LIST OF TERMS
1. Place the unit in position and secure it firmly
(21). The current should be off.
2. After loosening the fixing knob (15) choose the
flat- or saddle-stapling position on the table
(16). When the table is re-set the triggers (9)
must be pushed back to their innermost posi-
tion. Check that the table is correctly placed on
the anvil (8) and in the catch-plate (19).
3. The table (16) has 4 paper gauges which can
be adjusted sideways. The two gauges (18) on
the front edge are moved by pressing the lower
part. When not in use the gauges can be
moved out of the way by pushing them to the
outer edge and turning. The two paper gauges
(17) on the short sides of the table can be
moved sideways if first turned.
1. Remove dust, loose staples and other particles
which may have collected in the unit.
2. Lubricate the Insert stapler with a few drops of
thin oil after about 10,000 staplings, as shown
in the sketch. Wipe off excess oil.
A. Test the function of the insert stapler by hand.
1. Remove staples stuck in the outlet. Check that
correct staples have been used and that the
staple outlet is undamaged.
2. Change the insert stapler when damaged or
worn.
B. The operating system. Check that.
1. the unit is receiving current, and that the
switch is on (the pilot light comes on)
2. the sight-shield is down.
3. the correct method of activating is used. If the
foot control or opto cable is connected the trig-
ger will not operate.
4. the triggers return forward eastly after activa-
ting. Both must return to "stop' before the next
stapling.
5. correct impact force has been chosen. If the
faults remain, return the unit to your supplier or
to an authorised service man Do not use a
machine with a faulty connecting cable or plug.
1. Remove the locking plate (13) with its screw (5).
2. Change the insert staplen Press the plunger (28)
upwards when entering the new insert stapler.
3. Fasten the locking plate (13).
RAPID 106-USING THE TABLE
CHANGING THE INSERT STAPLER - RAPID 106
BREAKDOWNS
CHANGING THE INSERT STAPLER - RAPID 105
MAINTENANCE
12
11
10
9
13
1. Remove the fixing knob (15) with screw and
remove the table (16)
2. Loosen the two screws (26) and pull out the
insert stapler. Press up the plunger (28) and
remove the Insert stapler.
3. Fit the new insert stapler by first inserting the
catch-plate (19) in the up position over the anvil
(8).
4. Press up the plunger (28) and lower the catch-
plate (19) with the narrow pan pointing into the
machine.
5. Push in the insert stapler while holding up the
plunger. Impotant! Be sure that the narrow
part of the catch-plate enters its guide hole.
6. To maintain perfect stapling it is necessary to
adjust the position of the insert stapler towards
the anvil. This adjustment is achieved by using
the guide plate (27) enclosed with the machine.
Open the magazine and insert the guide plate
from underneath in the magazine outlet. Insert
magazine. Press down the insert stapler and
make sure that the guide plate fits well into the
anvil. Keep insert stapler pressed to the anvil
and tighten the mounting screws (26). Remove
the guide plate from magazine and do a few
trial staplings to check proper function.
7. Fit the table in pIace. NOTE: the table's strut.
Screw and fixing knob (15) must be positioned
in front of the tubular stand.
Equivalent noise level dB(A) at maximum
capacity and power.
Ex. 1440 staples per 8 hours give 70dB(A) (A106)
Noise measurement made according to ISO
7779 with supplement proposal "Electrical
staplers: Noise test code". The 70 dB(A)
equivalent noise level is a German requirement
for maximum noise level in common areas such
as shops, airport check in, receptions and other
simular areas.
RAPID A105/A106
A105 A106
80
90
70
60
50
STAPLES/8h
15000
1500
150
15
Содержание 105E
Страница 1: ...RAPID 105E OPERATION MANUAL 106E...