For non-conduit installations, plug the detachable
AC line cord into the receptacle on the rear of the
control unit. Plug the other end of the line cord into
a properly grounded 120 volt AC outlet.
>
Due to variations in source connec-
tions, European units are shipped without
an AC line cord. When selecting a line cord
for these units, select one that has the ap-
propriate source connector at the plug end,
and an IEC-60320 C13 connector at the
control unit end of the cord. The cord
should be rated for at least 60
°
C, have
0.8mm
2
(18 AWG) minimum conductors,
and be less than 6m (20 ft.) in length.
N O T E
N O T E
N O T E
N O T E
N O T E
2. Remove the mounting hardware from the AC
inlet receptacle and remove it from the rear of the
control unit.
3. Install the Conduit Adapter Plate (supplied) in
the hole where the AC inlet receptacle was removed
(see Figure 10c).
4. Install the AC input wiring (0.8mm
2
(18 AWG)
minimum) through the Conduit Adapter Plate using
conduit and wire to TB1 as follows:
Hot/Line
to TB1-L1
Neutral/Common to TB1-N
Ground
to TB1-EARTH GROUND
>
In general, conduit must be used for ap-
proved AC installation, however, if national
and local codes permit, the AC power may
be supplied via the factory supplied line
cord. If conduit is utilized, the control unit
AC input wiring may be routed through an
optional explosion proof switch mounted on
or near the spray booth where it will be con-
venient to the operator.
N O T E
N O T E
N O T E
N O T E
N O T E
For installations where it is required to run the AC
input wiring in conduit, perform the following:
1. Ensure the AC line cord is unplugged
Ensure the AC line cord is unplugged
Ensure the AC line cord is unplugged
Ensure the AC line cord is unplugged
Ensure the AC line cord is unplugged and
remove the AC inlet receptacle wiring from TB1-N,
TB1- L1, and TB1-EARTH GROUND (see Figures
10a and 10b).
INTERLOCKS
INTERLOCKS
INTERLOCKS
INTERLOCKS
INTERLOCKS
Interlocks required by code are as follows:
• Booth fan interlock - When the booth fan is on,
a contact closure is made.
• Conveyor interlock - when the conveyor is
moving a contact closure is made.
• Solvent interlock - When solvent supply to the
applicator is off, a contact closure is made.
>
When using conduit to route the AC in-
put wiring to the control unit, the last several
feet of conduit attached to the control unit
should be of a flexible type, such that the
control unit chassis can still be slid out of its
enclosure for testing and set-up purposes.
N O T E
N O T E
N O T E
N O T E
N O T E
Safety Ground
Safety Ground
Safety Ground
Safety Ground
Safety Ground
Crimp the appropriate terminal onto the ground
wire assembly and install from the control unit
ground lug, located on the back of the control unit,
to a true earth ground.