CAUTION

!

WA R N I N G

!

NOTE

SAFETY PRECAUTIONS

Before operating, maintaining or servicing any Ransburg 

electrostatic coating system, read and understand all of the 

technical and safety literature for your Ransburg products. 

This manual contains information that is important for you 

to know and understand. This information relates to 

USER 

SAFETY

 and 

PREVENTING EQUIPMENT PROBLEMS

.  

To help you recognize this information, we use the following 

symbols.  Please pay particular attention to these sections.

A WARNING! states information to alert you to 

a situation that might cause serious injury if 

instructions are not followed.

A CAUTION! states information that tells how to 

prevent damage to equipment or how to avoid a 

situation that might cause minor injury.

A NOTE is information relevant to the procedure 

in progress.

While this manual lists standard specifications and service 

procedures, some minor deviations may be found between 

this literature and your equipment. Differences in local codes 

and plant requirements, material delivery requirements, etc., 

make such variations inevitable. Compare this manual with 

your system installation drawings and appropriate Ransburg 

equipment manuals to reconcile such differences.

Careful study and continued use of this manual will provide a 

better understanding of the equipment and process, resulting 

in more efficient operation, longer trouble-free service and 

faster, easier troubleshooting.  If you do not have the manuals 

and safety literature for your Ransburg  system, contact your 

local Ransburg representative or Ransburg.

WA R N I N G

!

WA R N I N G

!

 

†

The user 

MUST

 read and be familiar with the 

Safety Section in this manual and the Ransburg 

safety literature therein identified. 

 

†

This equipment is intended to be used by 

trained personnel 

ONLY

 

†

This manual 

MUST

 be read and thoroughly un-

derstood by 

ALL

 personnel who operate, clean or 

maintain this equipment! Special care should be tak-

en to ensure that the 

WARNINGS

 and safety require-

ments for operating and servicing the equipment are 

followed. The user should be aware of and adhere 

to 

ALL

 local building and fire codes and ordinances 

as well as

 NFPA-33 AND EN 50176 SAFETY STAN-

DARDS, LATEST EDITION

, or applicable country 

safety standards, prior to installing, operating, and/or 

servicing this equipment.

 

†

The hazards shown on the following pages may 

occur during the normal use of this equipment. Please 

read the hazard chart beginning on page 2.

SAFETY

LN-9223-00-R12  (04/2018)

4 / 22

www.carlisleft.com

SAFETY

EN

Содержание DR-1

Страница 1: ...nt carefully read SAFETY PRECAUTIONS starting on page 4 and all instructions in this manual Keep this Service Manual for future reference Model 74151 DR 1 Fluid Regulator LN 9223 00 R12 04 2018 1 22 w...

Страница 2: ...changed from revision LN 9223 00 11 to revision LN 9233 00 R12 Reasons for this change are noted under Manual Change Summary inside the back cover of this manual LN 9223 00 R12 04 2018 2 22 www carlis...

Страница 3: ...ry Procedures 12 Disassembly Procedures 12 Regulator Cross Sectional View 13 Assembly Procedures 14 Test Procedures 15 Preventive Maintenance 15 Troubleshooting Guide 16 PARTS IDENTIFICATION 18 20 Reg...

Страница 4: ...dappropriateRansburg equipment manuals to reconcile such differences Careful study and continued use of this manual will provide a betterunderstandingoftheequipmentandprocess resulting in more efficie...

Страница 5: ...nce Spray booth ventilation must be kept at the rates required by NFPA 33 OSHA country and local codes In addition ventilation must be maintained during cleaning operations using flammable or combusti...

Страница 6: ...t inadvertent arcing that is capable of causing fire or explosion is lost if the current overload sensitivity is not properly set Frequent power supply shutdown indicates a problem in the system which...

Страница 7: ...t be wearing or carrying any ungrounded metal objects When using an electrostatic handgun operators must assure contact with the handle of the applicator via conductive gloves or gloves with the palm...

Страница 8: ...e is contact with the skin Follow the requirements of the Safety Data Sheet supplied by coating material manufacturer Adequate exhaust must be provided to keep the air free of accumulations of toxic m...

Страница 9: ...ameter W Fittings 3 3 8 inch 86mm Air Pressures Variable by Control Manual or Automatic 100 psi 7 bar max Fluid Input 300 psi 20 7 bar max 10 psi minimum above output pressure Fluid Output Variable by...

Страница 10: ...0 600 400 200 0 FLOW CC MIN DR 1 Flow vs Signal Pressure 200 100 9 12 15 21 26 32 37 42 48 54 59 65 70 75 81 SIGNAL PRESSURE PSI Viscosity 40 sec Zahn 2 15ft 1 4 I D tubing 093 orfice Viscosity 25 sec...

Страница 11: ...s a lower more precise flow response curve Fluid output as a result is less likely to be affected by pilot signal errors An increase in the ratio i e from 1 2 to 1 4 provides a lower slope in the flow...

Страница 12: ...parts it may be necessary to use a small screwdriver Care should be taken to NOT damage the components Damage of these parts may cause leakage 2 Remove Item 1 cap Item 9 upper diaphragm Item 2 spacer...

Страница 13: ...Figure 1 Regulator Cross Sectional View 14 2 18 8 7 6 10 1 16 9 5 4 15 17 3 10 10 11 13 12 LN 9223 00 R12 04 2018 13 22 www carlisleft com MAINTENANCE EN...

Страница 14: ...nto Item 3 lower housing withtheballendagainstItem11 regulating seat 10 Place Item 10 o ring on Item 13 retaining plug 11 Place Item 12 spring into Item 3 lower housing over Item 11 regulating needle...

Страница 15: ...fore installation 6 month intervals 4 Gradually increase air pressure on either of the air lines and visually observe a gradual increase in fluid flow If regulator does not perform satisfactorily insp...

Страница 16: ...ured Item 14 center diaphragm Incorrect regulator ratio Fluid supply pressure to low Air pilot to low Flush clean Remove and clean or replace Check air pilot signal Rebuild regulator Rebuild regulator...

Страница 17: ...ragm Ruptured Item 14 center diaphragm Inconsistent air pilot Inconsistent fluid supply pressure Incorrect regulator ratio Fluid supply pressure too high Rebuild regulator Rebuild regulator Rebuild re...

Страница 18: ...PARTS IDENTIFICATION Figure 2 Regulator Cross Sectional View 14 2 18 8 7 6 10 1 16 9 5 4 15 17 3 10 10 11 13 12 LN 9223 00 R12 04 2018 18 22 www carlisleft com PARTS IDENTIFICATION EN...

Страница 19: ...1 2 75374 01 Ratio 1 3 75374 06 Ratio 1 4 75374 02 Ratio 1 6 75374 03 Ratio 1 8 74155 00 Ratio 1 10 74155 01 6 Diaphragm Retainer Lower 74156 00 1 7 Diaphragm Retainer Center 74231 00 1 8 Diaphragm L...

Страница 20: ...16 Screw Pan Head 74183 20C 1 17 Gasket 72135 00 2 18 Bleed Spacer 74232 00 1 20 Paint Fitting not included For Select Options Below 3 16 OD Tubing 70589 04 1 4 OD Tubing 70589 05 3 8 OD Tubing 70589...

Страница 21: ...RY No Change Description LN 9223 00 R12 Replaces LN 9223 00 11 with the folowing changes 1 Change to new format design All Pages 2 New Image Cover Page s LN 9223 00 R12 04 2018 21 22 www carlisleft co...

Страница 22: ...chnologies is a global leader in innovative finishing technologies Carlisle Fluid Technologies reserves the right to modify equipment specifications without prior notice DeVilbiss Ransburg MS BGK and...