NOTE
NOTE
For those installations where it is required to run the
AC input wiring in conduit, perform the following:
1. Ensure the AC line cord is unplugged and remove
the AC inlet receptacle wiring from TB1-N, TB1-L1
and TB1-EARTH GROUND (See Figures 9 and 10).
2. Remove the mounting hardware from the AC inlet
receptacle and remove it from the side of Controller.
3. Install the Conduit Adapter Plate (See Accessories
Section) in the hole where the AC inlet receptacle
was removed (see Figure 11).
4. Install the AC input wiring (0.8mm
2
(18AWG) min-
imum) through the Conduit Adapter Plate using
conduit and wire to TB1 as follows:
In general, conduit must be used for approved
AC installation, however, if national and local
codes permit, the AC power may be supplied
via the factory supplied line cord. If conduit is
utilized, the Controller AC input wiring may be
routed through an optional explosion proof switch
mounted on or near the spray booth where it will
be convenient to the operator.
Hot/Line
to TB1-L1
Neutral/Common to TB1-N
Ground
to TB1-EARTH GROUND
Figure 9: Location of TB1 & TB2 in Controller
Figure 11: Installation of Conduit Adapter Plate
Interlocks should be DRY CONTACTS and
should be rated to handle 1 amp.
Interlock series resistance should not
exceed 20kΩ.
Figure 10: TB1 Interlock Wiring
SIDE VIEW
CP-17-02
15
9060 Classic High Voltage Controller -
INSTALLATION