RANS S-20 RAVEN
TEXT MANUAL
09
/01/2013
11B-03
Surface clearance
9.
Refer to
FIGURE 11B-09
•
The minimum clearance between elevator and horizontal stabilizer
is 0.060” all the way along the hinge line.
•
The minimum clearance between the elevator balance horn and the
horizontal stabilizer tip is 3/16”.
Static balance
10.
Both elevators must be 100% static balanced in reference to the hinge
line.
11.
For instructions, refer to Section 11 -
ELEVATOR MASS BALANCE
.
Operational check
12.
Move the controls in the cockpit throughout the full range of deflection.
Check for:
•
Correct deflections of control surfaces.
•
Interference of controls, linkages, surfaces with other components.
•
Excessive friction.