background image

5.0. MOUNTING AND CONNECTION OF DIAPHRAGM PUMP 

Pump  should  fixed  firmly  to  the  ground  or  platform  and  should  be  fitted  in  a  perpendicular 
position as shown in Figure 5. Never place the pump at an angle, lying on the ground or upside 
down.  The  pump  will  not  run  correctly  and  check  valves  and  diaphragms  will  wear  out  very 
quickly due to constant dry running.

 

 

When  installing  the  pump  ensure  that  it  is  balanced  correctly  when  using  a  lifting 
device.(Figure 5)

 

 

Şekil 5 – Diaphragm pump mounting position

 

5.1. Mounting Pump

 

Keep the points below in mind when choosing the pump mounting place. 

1-

 Easy access when operating or maintaining. 

2- (Air valves, inlet and outlet manifolds of air and fluid, etc.) 

3-

 Pump weight in relation to the ground/platform. 

4-

 Vibration emission to the ground and other equipment. 

 

 

 

 
 
 
 
 
 
 
 
 

 

Figure 6 

– Minimum space requirement around the diaphragm pump. 

 

 

Содержание B15-PVX

Страница 1: ...PHRAGM PUMP 5 0 MOUNTING AND CONNECTING OF DIAPHRAGM PUMP 6 0 INSTRUCTIONS AND MANUAL OF DIAPHRAGM PUMP 7 0 ASSEMBLY AND DISMANTLING OF PARTS 8 0 PERIODIC MAINTENANCE 9 0 STORAGE OF DIAPHRAGM PUMP 10...

Страница 2: ...t surpass the strength of minimum system compound j Learn hazards or potential dangers of your fluid k Choose the wet pump parts material resistant to your fluids Refer to the Proper Material Fluid Ch...

Страница 3: ...or physical damage Use only genuine RAN parts and accessories WARNING Running the pump with hot liquids may cause the surface of the pump heat up above 80 Co Under these conditions it is pump owner s...

Страница 4: ...agm Material Temperature limits BUNA N 12 2 C 65 6 C PTFE teflon 4 C 104 4 C Santoprene 28 9 C 104 4 C Polyurethane 12 2 C 65 6 C V TON 40 C 176 7 C Neoprene 17 8 C 93 3 C EPDM 51 1 C 137 8 C 3 0 DIAP...

Страница 5: ...rces diaphragm A away from the center block while at the same time the connected shaft pulls diaphragm B to the center block Diaphragm A is now on its discharge stroke Diaphragm A forces the inlet val...

Страница 6: ...MATERIAL DIAPHRAGM MATERIAL B 1 2 A Aluminium 0 Buna N C 3 4 P Polypropylene 1 PTFE teflon BODY MATERIAL D 1 C Cast Iron S Santoprene INLET OUTLET E 1 S Stainless Steel F 2 PV PVDF G 3 3 3 Main parts...

Страница 7: ...0 HANDLING MOVING OPENING THE PACKAGE OF DIAPHRAGM PUMP Handle the pump from manifolds to move We pack the pumps into carton boxes Figure 4 Pump package Pump package must be at least 300 grams and pro...

Страница 8: ...ly due to constant dry running When installing the pump ensure that it is balanced correctly when using a lifting device Figure 5 ekil 5 Diaphragm pump mounting position 5 1 Mounting Pump Keep the poi...

Страница 9: ...the skin injury from moving parts or contamination from hazardous fluids See Fig 7 1 Refer to the Figure 7 for the connection scheme Fix these accessories to the wall or to a bracket The air line fee...

Страница 10: ...ump operation 4 At inlet fluid pressures greater than 15 psi 0 1MPa 1 bar diaphragm life will be shortened 5 5 2 Fluid discharge line 1 Use a conductive fluid hose or pipe The pump fluid outlet is 1 2...

Страница 11: ...outlet hose can cause the pump to stop or even reverse operation In this case a pressure relief system bypass line MUST be installed When using long pipelines that may be pumping cold fluid with hose...

Страница 12: ...m diameter of 1 2 inch 13 mm ID If a hose longer than 4 5 m is required use a larger diameter hose Avoid bending the hose sharply 3 Place a suitable conductive container at the end of exhaust hose to...

Страница 13: ...fluid is affected by water Follow the instructions in Starting and Adjusting the Pump 6 2 Starting and adjusting the pump 1 Check pump grounding before use 2 Check fittings to be sure they are tight...

Страница 14: ...d b Before pulling out the hose from the pump put a container under the pump Pull it out slowly and carefully 7 0 ASSEMBLY AND DISMANTLING OF PARTS WARNING Before service and maintenance always reliev...

Страница 15: ...nspect the diaphragm shaft for wear or scratches If it is damaged inspect the bearings in place 9 Remove the tap which holds the pilot shaft and diaphragm shaft 10 Clean all parts and inspect for wear...

Страница 16: ...Push a tap with your finger until the valve core comes out 4 Valve core should move in the valve body little bit tightly If it moves loosely the teflon o rings must be worn They must be changed also 5...

Страница 17: ...egulator 2 Check if there is water or moisture in the filter 3 Check the air pressure set value of the pressure regulator 4 After you finish work clean the pump by pumping a suitable solvent for your...

Страница 18: ...Loose diaphragm shaft bolt Tighten or replace Damaged o ring Replace 5 Fluid in exhaust air Diaphragm is ruptured Replace Loose diaphragm shaft bolt Tighten or replace Damaged o ring Replace 6 Pump f...

Страница 19: ...ther clean the pump after you are done 10 0 PRECAUTIONS ON DISPOSING OF THE DIAPHRAGM PUMP Follow these precautions before disposing of the pump 1 Discharge the pump completely 2 Disconnect all the ho...

Страница 20: ...515 1 Inlet elbow manifold 2 18 B3214 Valve reset button 1 38 Center manifold O ring 4 19 B3012 Valve gasket 1 39 B3513 1 Center manifold 2 20 Valve fixing bolt 4 40 B3514 1 Outlet elbow manifold 2 Fi...

Страница 21: ...21 Figure 13b Pump assembly scheme for RAN 1 2...

Страница 22: ...22 ATTACHMENT 1 1 2 DIAPHRAGM PUMP PERFORMANCE CHARTS Reduce the flow rate by 20 if there are Teflon diaphragms on your pump...

Страница 23: ...If inspection of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportatio...

Страница 24: ...Gisan Makine San Tic Ltd ti Birlik Sanayi Sitesi 3 Cadde No 83 Beylikd z stanbul Turkey Tel 00 90 212 875 03 17 pbx Faks 00 90 212 875 03 18 E mail Web info ranpump com www ranpump 25082012...

Отзывы: