11
Aldis
Tutor
II
Service
©M.Ginda
08/02/2008
WWW.Karillon.com
Both bearing plates and the rotor can be removed from the armature.
Clean any residue from the bearing plates and the motor spindle. Be careful
not to lose the two fibre washers and the steel shim.
After brushing clean the armature the spindle of the rotor can be lightly oiled
(don’t apply too much) and the motor re-assembled.
Check the motor can be spun freely by hand. Re fit the motor to the now clean
and repaired housing, take care not to over tighten the fixing nuts as this can
damage the plastic housing.
Fit the fan back to the motor, gently tapping it onto the spindle. When
positioned correctly there should be a 2 to 3mm gap between the end of the
blades and the metal cover plate. Check the fan spins without fouling on the
cover plate then fit the five screws to retain the plate.
STEP 11
Re fit the primary heat filter if you have not already done so.
Re assemble the lamp housing, fan unit and baffle plate into the main
projector body.
Remember to locate the two cable grommets into the relevant locations.
Ensure the cables are not trapped under anything before replacing the screws