2. In accordance with the text prompt and symbol image install the calibration plate
in the desired position. The brightness of the images of calibration plate can be
adjusted with exposure controller. You should not allow very dark images or
images with excessive brightness areas. Press the Capture button. Original plate
position - the position at the working distance from the scanner (marking on the
view from cameras matches the markers on the plate), the cross is projected on
the central marker.
3. If the plate placement is incorrect a error message will appear. Correct the
placement and repeat the step.
In
case
if
not
all
marks
are
found
on
the
image,
you
will
also
see
the
error
message.
It
may
mean
the
following:
●
not
all
markers
are
visible
on
one
of
the
snapshots,
●
not
all
markers
are
lit
by
the
projector,
●
calibration
plate
is
mounted
at
large
angle
to
the
scanner,
●
plate
is
too
close
or
too
far
from
the
scanner
-
the
image
is
not
sharp,
the
plate
is
damaged
or
dirty.
Please
correct
all
deficiencies
and
press
Capture
.
24