20
8. Technical Data
The hob is an independent Class 3 built-in unit.
This hob is category II2H3+
It is supplied set for group H natural gas. A conversion kit from NG to LP is available for the hob.
INSTALLER:
Please leave these instructions with the user.
DATA BADGE LOCATION:
Base of the hob.
COUNTRY OF DESTINATION:
GB/IE
Connections
Gas
Electric
Rp ½ at rear right-hand side
230V~50Hz
Gas
Electric
Natural Gas
20 mbar
230V~50Hz
Butane
29 mbar
Propane
37 mbar
(See appliance data badge for test pressures)
Dimensions
Outside
Inside
Width
580 mm
550 mm
Length
500 mm
470 mm
Depth
50 mm from top
40 mm
Mass (kg)
10
Space for fixing
See Positioning of the Hob
“Fig. 5.1” on page 10
Minimum space above hotplate
See Positioning of the Hob
“Fig. 5.1” on page 10
Ratings
Natural Gas
L.P. Gas
Hotplate
Injector
Injector
Wok Burner
3.8 kW
135
3.8 kW (277 g/h)
98
Semi-rapid Burners
1.75 kW
97
1.75 kW (127 g/h)
65
Auxilliary Burner
1.0 kW
72
1.0 kW (73 g/h)
50
Gas burner inputs based on Gross Calorific Value