10
INSTALLATION
Check the appliance is electrically safe and gas sound when you have finished.
Positioning the Hob
It is recommended that the hob be installed in a worktop
with a minimum thickness of 38 mm and depth of 600 mm.
The cut-out dimensions and the recommended minimum
clearances from the hob to nearby surfaces are shown in (
Fig.
5.1
) and (
Fig. 5.2
).
NOTE:
If installing the hob over a standard cabinet, you may
have to remove part of the cabinet panels to allow the unit to
fit correctly.
NOTE:
Gap between the cut-out and back of the wall
MUST
be 60 mm (
Fig. 5.1
).
If installing a built-in oven directly under the hob, a minimum
thickness of 38 mm worktop is required and
must have an
air gap of 10 mm
between the oven and the bottom of the
hob (
Fig. 5.2
).
If no built-in oven is installed underneath, and If the worktop
surface used has less than a 38 mm is used
a 10 mm air gap
is still required
(
Fig. 5.2
).
NOTE:
If the built-in hob is being installed directly above
a built-in oven, an additional spacer (not supplied) may be
required to maintain
a clearance of 10 mm
between the
underside of the built-in hob and the top of the built-in oven
Fig. 5.3
.
n
n
There should be a minimum air gap of 10 mm under
the hob. Failure to maintain a suitable clearance may
impair the performance of the hob.
Any hob hood should be installed in accordance with the
hood manufacturer’s instructions.
Any splashback must be fitted in accordance with the
manufacturers instructions. Allowance should be made for
the additional height of the flue trim, which is fitted to the
cooker hob.
Surfaces of furniture and walls at the sides and rear of the hob
should be heat, splash and steam resistant. Certain types of
vinyl or laminate kitchen furniture are particularly prone to
heat damage and discolouration.
We cannot accept responsibility for damage caused by
normal use of the hob to any material that de-laminates
or discolours at temperatures less than 65°C above room
temperature.
For safety reasons curtains must not be fitted immediately
behind the hotplate.
410 mm
650 mm
60 mm
75 mm
560 mm
500 mm
470 mm
550 mm
580 mm
480 mm
10 mm
Clearance
Door
Wall
65 mm
Space for
connections
Fig. 5.1
Fig. 5.2
Fig. 5.3
2 mm
Oven
*
Spacer
Hob Worktop
Front fascia
n
n
IMPORTANT
* To achieve a 10 mm gap clearance, a spacer may be
required when installing directly above a built-in oven.