WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON

Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.

11

Check in the ‘Technical Data’ section at the back of the 
instructions that the cooker is convertible to the gas you 
want to use.

This conversion must be performed by a suitably 
competent person, in accordance with these instructions 
and with the local supply company requirements.

Failure  to  convert  the  appliance  correctly  could 
invalidate  any  warranty  or  liability  claims  and  lead  to 
prosecution.
The  conversion  instructions  must  be  used  in  conjunction 
with  the  rest  of  the  appliance  instruction,  in  particular 
for  information  on  Standards,  cooker  positioning, 
connection,  hose  suitability,  etc.
When  servicing  or  replacing  gas-carrying  components, 
disconnect  from  the  gas  before  starting,  and  check  that 
the  appliance  is  gas  sound  after  completion.
Do  not  use  reconditioned  or  unauthorised  gas  controls.
Disconnect from the electricity supply before 
commencing servicing.

Before  electrical  reconnection,  check  that  the  appliance 
is  electrically  safe.

Injectors

Remove  burner  caps  and  heads.  Remove  old  jets.  Fit  the 
new  jets  (see Technical  Data  section  at  the  back  of  the 
book  for  correct  jets).  Reassemble  in  reverse  order. 

Tap Adjustment

Disconnect  from  the  electricity  supply.
Pull  off  all  the  control  knobs.  Insert  a  suitable  small 
flat  screwdriver  into  the  hole  in  the  end  of  the  control 
spindle,  and  turn  the  bypass  screw  on  each  control 
clockwise  to  the  stop  (Fig.6-1).  Refit  the  control  knob. 

Affix Label

Stick  the  LP  gas  label  over  the  natural  gas  part  of  the 
appliance  data  label.

Pressure Testing

Make  sure  that  the  appliance  is  gas  sound;  refer  to 

‘Pressure Testing’

  earlier  in  the  section.

Check  the  operation  of  all  the  burners.

6.  Conversion to LPG Gas

����������������������������������������

Fig.6-1

DocNo.071-0001 - LP gas conversion - BI hobs

Содержание RGG60

Страница 1: ...RGG60 Gas Hob User Guide Installation Service Instructions U109927 02...

Страница 2: ...ents 1 Before You Start 1 2 Hob Overview 3 3 Cleaning Your Hob 5 4 Troubleshooting 6 5 Installation 7 6 Conversion to LPG Gas 11 7 Circuit Diagram 12 8 Technical Data 13 9 Warranty After Sales Service...

Страница 3: ...Accessible parts will become hot during use and will retain heat even after you have stopped cooking Keep babies and children away from the hob and never wear loose tting or hanging clothes while the...

Страница 4: ...as a build up of fats and other foodstu s could result in a re Clean only the parts listed in this guide Clean with caution If a wet sponge or cloth is used to wipe spills on a hot surface be careful...

Страница 5: ...uld spark and light the gas If when you let go of the control knob the burner goes out then the safety device has not held in Turn the control to the o position and wait one minute then try again this...

Страница 6: ...he minimum recommended pan diameter is 120mm The maximum allowable pan base diameter is 250mm Hob Care The burner parts can be removed for cleaning see Cleaning your hob You should wipe the top surfac...

Страница 7: ...ny spillages immediately Hotplate Burners The burner heads and caps can be removed for cleaning Fig 3 1 Make sure they are absolutely dry before replacing them The single ring burners When re tting th...

Страница 8: ...ot there maybe something wrong with the power supply Are the sparker ignition electrode or burner slots blocked by debris Are the burner trim and caps correctly located See the section on Cleaning Hot...

Страница 9: ...Provision of Ventilation This appliance is not connected to a combustion products evacuation device Particular attention shall be given to the relevant requirements regarding ventilation In the UK Th...

Страница 10: ...position it has a maximum thickness of 50mm from the top of the work surface The cut out dimensions are shown in Fig 5 1 and the minimum clearances in Fig 5 2 The minimum recommended distances from th...

Страница 11: ...gas and electricity supply This information is on the data label xed to the underside of the hotplate Gas connection must comply with the relevant standards and regulations in force The gas connection...

Страница 12: ...er has been obtained from your supplier The colour of the correct fuse carrier is that of the coloured insert in the base of the fuse recess or stated elsewhere on the plug Always state this colour wh...

Страница 13: ...gas before starting and check that the appliance is gas sound after completion Do not use reconditioned or unauthorised gas controls Disconnect from the electricity supply before commencing servicing...

Страница 14: ...12 7 Circuit Diagram ArtNo 080 0015 RG60 RGG60 circuit diagram N L A B Spark generator Ignition switch DocNo 091 0001 Circuit diagram RG60 RGG60 gas...

Страница 15: ...bar See appliance data badge for test pressures Dimensions Overall height Above worktop 50mm Below worktop 50mm Overall width 620mm see Positioning of Cooker Overall depth 510mm Space for xing See Pos...

Страница 16: ...ce and the product code serial number The 2 years free maintenance for the operation of the appliance started from the date of purchase of this product Any cosmetic damage to the appliance must be rep...

Страница 17: ...15...

Страница 18: ...16...

Страница 19: ...17...

Страница 20: ...www rangemaster co uk ArtNo 000 0003 CE logo DocNo 000 0001 Back cover Rangemaster...

Отзывы: