INSTALLATION

Check the appliance is electrically safe and gas sound when you have finished.

Electrical Connections

This appliance must be installed by a qualified electrician 
to comply with the relevant Institute of Electrical 
Engineers (I.E.E.) regulations and also the local electricity 
supply company requirements.

 

WARNING: THIS APPLIANCE MUST BE EARTHED

Note: All external wiring must comply with the IEE 
Regulations for the Electrical Equipment of Buildings. 
Connection to the electrical supply can be made with either 
a plug and socket, or be permanently wired via a double pole 
switch. The hob is supplied with a 3-core cable, 900mm long.

If a replacement cable is fitted it must be 250V high 
temperature PVC (85°C), 1 mm²

 

minimum conductor size.

Plug Connection

For a plug connection a three-pin plug to BS 1363 with a 
capacity of not less than 13A must be used and fitted with a 
3A fuse, ‘ASTA’ approved to BS 1362.

After replacing the fuse the cover must be refitted. If the 
cover is lost, the plug must not be used until a replacement 
cover has been obtained from your supplier. The colour of the 
correct fuse carrier is that of the coloured insert in the base of 
the fuse recess, or stated elsewhere on the plug. Always state 
this colour when ordering a replacement fuse carrier.

IMPORTANT:

 The wires in the mains lead are coloured in 

accordance with the following code:

Green and yellow:  Earth

Blue: 

Neutral

Brown: 

Live

Hotplate

Check each burner in turn. There is a spark ignition system 
that works when the knob is pressed in. Each burner also has 
a special safety device that stops the flow of gas if the flame 
goes out. 

Push in and turn a control knob to the large flame symbol [

ArtNo.030-0012 - RG70 symbols

].

Keep holding the knob pressed in to let the gas through to 
the burner for few seconds. The igniter should spark and light 
the gas.

If, when you let go of the control knob, the burner goes out, 
the safety device has not held in. Turn the control to the 
OFF position and wait one minute, then try again this time 
holding in the control knob for slightly longer.

Customer Care

Please complete your contact details in the front of this 
section. Please inform the user how to operate the hotplate 
and hand over the instruction pack.

Thank you.

ArtNo.317-0012 - Hob fittings 1

�������

�������

���������

�����

������

�������

���

�������

���������

�����

���

�����

�����

Fig.5-4

Содержание RGG60

Страница 1: ...RGG60 Gas Hob User Guide Installation Service Instructions U109927 02...

Страница 2: ...ents 1 Before You Start 1 2 Hob Overview 3 3 Cleaning Your Hob 5 4 Troubleshooting 6 5 Installation 7 6 Conversion to LPG Gas 11 7 Circuit Diagram 12 8 Technical Data 13 9 Warranty After Sales Service...

Страница 3: ...Accessible parts will become hot during use and will retain heat even after you have stopped cooking Keep babies and children away from the hob and never wear loose tting or hanging clothes while the...

Страница 4: ...as a build up of fats and other foodstu s could result in a re Clean only the parts listed in this guide Clean with caution If a wet sponge or cloth is used to wipe spills on a hot surface be careful...

Страница 5: ...uld spark and light the gas If when you let go of the control knob the burner goes out then the safety device has not held in Turn the control to the o position and wait one minute then try again this...

Страница 6: ...he minimum recommended pan diameter is 120mm The maximum allowable pan base diameter is 250mm Hob Care The burner parts can be removed for cleaning see Cleaning your hob You should wipe the top surfac...

Страница 7: ...ny spillages immediately Hotplate Burners The burner heads and caps can be removed for cleaning Fig 3 1 Make sure they are absolutely dry before replacing them The single ring burners When re tting th...

Страница 8: ...ot there maybe something wrong with the power supply Are the sparker ignition electrode or burner slots blocked by debris Are the burner trim and caps correctly located See the section on Cleaning Hot...

Страница 9: ...Provision of Ventilation This appliance is not connected to a combustion products evacuation device Particular attention shall be given to the relevant requirements regarding ventilation In the UK Th...

Страница 10: ...position it has a maximum thickness of 50mm from the top of the work surface The cut out dimensions are shown in Fig 5 1 and the minimum clearances in Fig 5 2 The minimum recommended distances from th...

Страница 11: ...gas and electricity supply This information is on the data label xed to the underside of the hotplate Gas connection must comply with the relevant standards and regulations in force The gas connection...

Страница 12: ...er has been obtained from your supplier The colour of the correct fuse carrier is that of the coloured insert in the base of the fuse recess or stated elsewhere on the plug Always state this colour wh...

Страница 13: ...gas before starting and check that the appliance is gas sound after completion Do not use reconditioned or unauthorised gas controls Disconnect from the electricity supply before commencing servicing...

Страница 14: ...12 7 Circuit Diagram ArtNo 080 0015 RG60 RGG60 circuit diagram N L A B Spark generator Ignition switch DocNo 091 0001 Circuit diagram RG60 RGG60 gas...

Страница 15: ...bar See appliance data badge for test pressures Dimensions Overall height Above worktop 50mm Below worktop 50mm Overall width 620mm see Positioning of Cooker Overall depth 510mm Space for xing See Pos...

Страница 16: ...ce and the product code serial number The 2 years free maintenance for the operation of the appliance started from the date of purchase of this product Any cosmetic damage to the appliance must be rep...

Страница 17: ...15...

Страница 18: ...16...

Страница 19: ...17...

Страница 20: ...www rangemaster co uk ArtNo 000 0003 CE logo DocNo 000 0001 Back cover Rangemaster...

Отзывы: