EN
7
7
RECYCLING VERSION AIR OUTLET
To install the hood in recycling version, the optional charcoal
filter kit must be purchased.
• Remove the chimney angle bracket.
• Screw the filter cover onto the air outlet, using four screws
12c
(2.9 x 12.5).
• Fix the air outlet grid
8
on the recirculation air outlet using the
2 screws
12d
(2,9 x 9,5) provided.
16
12c
12d
8
RECIRCULATION VERSION AIR OUTLET
• Insert the connection extension pieces laterally
14.1
in connec-
tion
15.
• Insert the Connector
15
into the Support bracket
7.3
and fix it
with a screw.
• Make sure that the outlet of the extension pieces
14.1
is hori-
zontally and vertically aligned with the chimney outlets.
• Connect the air outlet connection
15
to the hood body outlet
using either a flexible or rigid pipe ø 150 mm, the choice of
which is left to the installer.
• Ensure that the activated charcoal filters have been inserted.
ø 150
15
14.1
7.3
ELECTRICAL CONNECTION
• Connect the hood to the mains supply.
• Open the upper panel by pressing the
A
-key (See Part “USE” )
for at least 2 seconds.
• Remove the metal filters (See Part “MAINTENANCE”) and
make sure that the connector piece of the supply cable is cor-
rectly inside the hood socket.