Select Transmission Mode
Requires "Transmission Mode > Manual".
Selects the transmission mode.
illustrates, how the selected transmission mode affects
parameters.
Table 4-2: Transmission mode settings
Transmission mode
1
2
3
4
OFDM symbols per transmission frame
76
76
153
76
Number of carriers
1536
384
192
768
Transmission frame duration
96
ms
24
ms
24
ms
48
ms
Null symbol duration
1297
μ
s
324
μ
s
168
μ
s
648
μ
s
OFDM symbol duration
1246
μ
s
312
μ
s
156
μ
s
623
μ
s
Carrier spacing
1
kHz
4
kHz
8
kHz
2
kHz
Guard interval
246
μ
s
62
μ
s
31
μ
s
123
μ
s
Remote command:
[:SOURce<hw>]:BB:TDMB[:SPECial]:TRANsmission:MODE:SELECT
4.6
Global Connector Settings
The "Input Signal" dialog, the "Trigger/Marker/Clock" dialog and "Trigger In", "Marker"
and "Clock" tabs in "Baseband > ARB/Custom Digital Mod" configuration dialogs pro-
vide quick access to the related connector settings. Click the "Global Connectors" but-
ton to access the settings.
See also chapter "Global Connector Settings" in the user manual.
4.7
TS Player
To access the functionality
1. Select "Baseband > T-DMB/DAB > Input Signal".
2. Select "Source > TS Player".
3. Select "TS Player" button.
Opens the TS player dialog, where you can load files.
TS Player