T-DMB/DAB Configuration and Settings
R&S
®
SMCVB-K156
23
User Manual 1179.1029.02 ─ 02
4. Select "Input Signal > IP Channel x"
The tab provides settings necessary to configure IP channel
x
.
You can configure settings for 2 IP channels
x = 1 to 2
individually, see also "Input
Signal > General > IP TS Channel".
IP channel settings affect input IP data of the local IP data network. The settings are
independent from the used broadcast standard configuration.
Saving/recalling a certain IP channel or local IP data network configuration is not possi-
ble via the broadcast standard-specific functionality.
Use the global save/recall functionality instead, see section "Saving and Recalling
Instrument Settings" in the R&S
SMCV100B user manual.
The table below shows the availability of the tab in the broadcast standard configura-
tion.
Table 4-1: IP channel configuration support in broadcast standards
Baseband standard
"IP Channel x"
Baseband standard
"IP Channel x"
"ATSC/ATSC-M/H"
Yes
"T-DMB/DAB"
Yes
"ATSC 3.0"
No
"DVB-S"
Yes
"DTMB"
Yes
"DVB-S2"
Yes
"DVB-T"
Yes
"DRM"
No
"DVB-T2"
Yes
"Audio AM"
No
"ISDB-T"
Yes
"Audio FM"
No
See also:
●
Chapter 5.1.1, "How to Apply an External IP Input Signal"
●
Chapter 4.8, "Local IP Data Network Settings"