Remote Commands
R&S
®
FSW
857
User Manual 1173.9411.02 ─ 43
Usage:
Query only
CALCulate<n>:LIMit<li>:ACPower:ALTernate<ch>[:RELative]:STATe
This command turns the relative limit check for the alternate channels on and off.
You have to activate the general ACLR limit check before using this command with
CALCulate<n>:LIMit<li>:ACPower[:STATe]
.
Suffix:
<n>
.
irrelevant
<li>
irrelevant
<ch>
1..n
Alternate channel number
Parameters:
<State>
ON | OFF | 1 | 0
Relative limit check for lower alternate channel
*RST:
0
<State>
Manual operation:
See
See
CALCulate<n>:LIMit<li>:ACPower[:STATe]
<State>
This command turns the limit check for ACLR measurements on and off.
In addition, limits must be defined and activated individually for each channel (see
CALCulate<n>:LIMit<li>:ACPower:ACHannel[:RELative]:STATe
,
CALCulate<n>:LIMit<li>:ACPower:ALTernate<ch>[:RELative]:STATe
,
CALCulate<n>:LIMit<li>:ACPower:GAP<gap>[:AUTO]:ABSolute:STATe
,
CALCulate<n>:LIMit<li>:ACPower:GAP<gap>[:AUTO]:ACLR[:RELative]:
STATe
CALCulate<n>:LIMit<li>:ACPower:GAP<gap>[:AUTO][:
).
Suffix:
<n>
.
irrelevant
<li>
irrelevant
Parameters:
<State>
ON | OFF | 1 | 0
*RST:
0
Manual operation:
See
See
See