Sample Rate
Defines the I/Q data sample rate of the R&S
FSV/A. This value is dependent on the
and the defined signal source.
sample rate = analysis bandwidth / 0.8
For details on the dependencies see
Chapter 4.1.1, "Sample Rate and Maximum Usa-
ble I/Q Bandwidth for RF Input"
Remote command:
Analysis Bandwidth
Defines the flat, usable bandwidth of the final I/Q data. This value is dependent on the
defined
and the defined signal source.
analysis bandwidth = 0.8 * sample rate
Remote command:
Maximum Bandwidth
Defines the maximum bandwidth to be used by the R&S
FSV/A for I/Q data acquisition.
This setting is only available if a bandwidth extension option larger than 40
MHz is
installed, and only for sample rates (that is: <SymbolRate>*<CaptureOverview>) up to
128
MHz. Otherwise, the maximum bandwidth is determined automatically.
For details on the maximum bandwidth see
Chapter 4.1.1, "Sample Rate and Maxi-
mum Usable I/Q Bandwidth for RF Input"
"Auto"
(Default) All installed bandwidth extension options are enabled. The
currently available maximum bandwidth is allowed.
(See
Chapter 4.1.1, "Sample Rate and Maximum Usable I/Q Band-
"40 MHz"
Restricts the analysis bandwidth to a maximum of 40
MHz.
"200
MHz"
Restricts the analysis bandwidth to a maximum of 200
MHz.
Remote command:
Meas Time
Defines the I/Q acquisition time. By default, the measurement time is calculated as the
number of I/Q samples ( "Record Length" ) divided by the sample rate. If you change
the measurement time, the
is automatically changed, as well.
Remote command:
Record Length
Defines the number of I/Q samples to record. By default, the number of sweep points is
used. The record length is calculated as the measurement time multiplied by the sam-
ple rate. If you change the record length, the
is automatically changed, as
well.
Data Acquisition and Bandwidth Settings