¸FSH3
¸FSH6
Markers
Number of markers or delta markers
max. 6
Marker functions
peak, next peak, minimum,
center = marker frequency,
reference level = marker level, all markers to peak
Marker displays
normal (level), noise marker, frequency counter (count)
Trigger
free-running, video, external
Audio demodulation
AM (video voltage without AGC) and FM
Inputs
RF input
N female
Input impedance
50
W
VSWR
10 MHz to 3 GHz
10 MHz to 6 GHz
typ. 1.5
–
–
typ. 1.5
Trigger/external reference input
BNC female, selectable
Trigger voltage
TTL
Reference frequency
10 MHz
Required level
from 50
W
10 dBm
Outputs
AF output
3.5 mm mini jack
Output impedance
Open-circuit voltage
100
W
adjustable up to 1.5 V
Tracking generator
only models .13, .23, .26
Frequency range
5 MHz to 3 GHz
5 MHz to 6 GHz
Output level
model .13
model .23
model .26
f < 3 GHz
f > 3 GHz
–20 dBm (nominal)
0 dBm/–20 dBm, selectable
–10 dBm (nominal)
–20 dBm (nominal)
Step attenuator
model .26
3)
model .23
4)
20 dB step attenuator is adjustable in 1 dB steps
Output impedance
50
W
, nominal
Interfaces
RS-232-C optical interface
5)
Baud rate
1200, 2400, 9600, 19200, 38400, 57600, 115200 baud
Power sensor
7-contact female connector (type Binder 712)
13
Handheld Spectrum Analyzer ¸FSH
3)
As of serial no. 100500.
4)
As of serial no. 102314.
5)
Standard accessory: optical USB cable.