Quick Start Guide 1302.6163.62 - 04
2.15
R&S ESU
Preparing for Use
Connecting External Devices
3. If you no longer need the memory stick or if you want to transfer files to another computer,
simply disconnect the memory stick. Windows XP will automatically deactivate the driver. If
the drive is still selected in Explorer, an error message will appear indicating that the drive
is no longer available.
2.3.6 Connecting External Generators
The External Generator Control option (R&S FSP-B10) allows you to operate a number of
commercially available generators as a tracking generator on the R&S ESU. When suitable
generators are used, the R&S ESU thus allows scalar network analysis to be performed also
outside the frequency range of the internal tracking generator. Appendix
provides a list of generators supported by the option R&S FSP-B10.
The following figure shows the test setup:
The generator is controlled via the – optional – second GPIB interface of the R&S ESU
(= IEC2, supplied together with the option). With some Rohde & Schwarz generators, it is also
controlled via the TTL synchronization interface that is contained in the AUX CONTROL
interface of the R&S ESU.
• Using the TTL interface allows you to attain significantly higher
speeds than possible with a pure GPIB control, because the
frequency switching mechanism of the R&S ESU is directly coupled
to the frequency switching mechanism of the generator.
• To increase measurement accuracy, use a shared reference
frequency to operate the R&S ESU and the generator. If no
independent 10 MHz reference frequency is available, connect the
reference output of the generator to the reference input of the
R&S ESU and use
SETUP
–
REFERENCE EXT
to configure the
R&S ESU to implement the external reference.
0
1
2
3
4
5
6
7
8
9
.
-
ESC
1093.4495.03
FCTN
ENTER
CANCEL
GEN OUTPUT 50
Ω
AF OUTPUT
MEAS
TRIG
FREQ
MKR
AMPT
SPAN
MKR
MKR
BW
SWEEP
TRACE
LINES
DISP
FILE
GHz
MHz
kHz
Hz
-dBm
dBm
dB
dB..
CAL
SETUP
PRESET
HCOPY
SPECTRUM ANALYZER 9kHz . . . 3GHz
.
.
FSP
BACK
s
V
ms
mV
µs
µV
ns
nV
PREV
RF INPUT
50
EXT MIXER
MAX
+30 dBm / 50V DC
NEXT
KEYBOARD
PROBE
POWER
MAX 0V DC
MADE IN GERMANY
.
Ω
DUT
GPIB
TTL (optional)
GEN OUTPUT
RF INPUT
AUX /
TRIGGER
BLANK
MARKER IEC-BUS
IEC2
AUX
CONTROL
REF
REF IN
Reference Frequency
TTL (optional)
Reference Frequency
DUT
AUX /
TRIGGER
BLANK
MARKER
Содержание esu
Страница 1: ...R S ESU EMI Test Receiver Quick Start Guide Quick Start Guide Test Measurement 1302 6163 62 04 ...
Страница 26: ...R S ESU Contents 6 Quick Start Guide 1302 6163 62 04 ...
Страница 28: ......
Страница 32: ...R S ESU 0 4 Quick Start Guide 1302 6163 62 04 ...
Страница 88: ...R S ESU Preparing for Use Operating System Properties 2 38 Quick Start Guide 1302 6163 62 04 ...
Страница 104: ...R S ESU Basic Operation Setting Parameters 4 12 Quick Start Guide 1302 6163 62 04 ...
Страница 175: ...Quick Start Guide 1302 6163 62 04 6 33 R S ESU LAN Interface Manual Operation of the R S ESU with XP Remote Desktop ...
Страница 178: ...R S ESU LAN Interface Manual Operation of the R S ESU with XP Remote Desktop 6 36 Quick Start Guide 1302 6163 62 04 ...
Страница 201: ...Quick Start Guide 1302 6163 62 04 R S ESU Appendix Appendix ...
Страница 202: ...Quick Start Guide 1302 6163 62 04 R S ESU Appendix ...