Remote Control
R&S
®
ESR
675
User Manual 1175.7068.02 ─ 12
........................................................................................ 677
......................................................................................... 678
............................................................................................. 678
[SENSe:]SCAN<range>:BANDwidth:RESolution
<Bandwidth>
This command defines the measurement bandwidth for a particular scan range.
Suffix:
<range>
.
1...10
Selects the scan range.
Parameters:
<Bandwidth>
Range:
10 Hz to 10 MHz
*RST:
9 kHz
Example:
SCAN4:BAND:RES 1MHz
Defines a measurement bandwidth of 1 MHz for the 4th scan
range.
[SENSe:]SCAN<range>:INPut:ATTenuation
<Attenuation>
This command defines the attenuation level for a particular scan range.
Suffix:
<range>
.
1...10
Selects the scan range.
Parameters:
<Attenuation>
dBmin to dBmax
Range:
Att(min) to Att(max)
*RST:
10 dB
Example:
SCAN4:INP:ATT 30dB
Defines an attenuation level of 30 dB for the 4th scan range.
[SENSe:]SCAN<range>:INPut:ATTenuation:AUTO
<State>
This command turns auto ranging in a particular scan range on and off.
Suffix:
<range>
.
1...10
Selects the scan range.
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
SCAN4:INP:ATT:AUTO OFF
Turns off auto ranging in the 4th scan range.