The test set-up for measuring the asymmetrical impedance and phase angle is shown
in Figure 5. For R&S ENY81-CA6 it is shown in Figure 6. The network analyzer is
connected on the EUT port of the ISN by using the Impedance Measurement Adapter
“Jig IMA U0”. The measurement is performed with open and shorted AE port using the
termination adapter “A-OPEN“ and “A-SHORT” or “Jig TRA U0-150” for R&S ENY81-
CA6 respectively. The impedance requirements must be met in both cases and have to
be performed for each LCL adapter individually.
Fig. 5
Test set-up for Asymmetrical Impedance and Phase in accordance with CISPR 16-1-2
Fig. 6
Test set-up for Asymmetrical Impedance and Phase in accordance with CISPR 16-1-2 for
R&S ENY81-CA6