CONFigure:LTE:MEAS<i>:MEValuation:LIMit:SEMask:LIMit<no>:CAGGregation:
CONFigure:LTE:MEAS<i>:MEValuation:LIMit:SEMask:LIMit<no>:ADDitional<Table>:
CAGGregation:CBANdwidth<Band1>:CBANdwidth<Band2>
.................................... 650
CONFigure:LTE:MEAS<i>:MEValuation:LIMit:SEMask:LIMit<no>:ADDitional<Table>:
.............................................................................. 652
CONFigure:LTE:MEAS<i>:MEValuation:LIMit:ACLR:UTRA<no>:CAGGregation:
CBANdwidth<Band1>:CBANdwidth<Band2>
<RelativeLevel>,
<AbsoluteLevel>
Defines relative and absolute limits for the ACLR measured in the first or second adja-
cent UTRA channel, depending on <no>.
The settings are defined separately for each channel bandwidth combination of the
aggregated channels.
Suffix:
<no>
.
1..2
Selects first or second adjacent UTRA channel
<Band1>
150,200
First channel bandwidth in 0.1 MHz
<Band2>
100,150,200
Second channel bandwidth in 0.1 MHz
For <Band1> = 150, only <Band2> = 150 is allowed
For <Band1> = 200, all <Band2> values are allowed
Parameters:
<RelativeLevel>
Range:
-256 dB to 256 dB
*RST:
32.2 dB (<no> = 1) / 35.2 dB (<no> = 2)
Default unit: dB
Additional parameters: OFF | ON (disables the limit check | ena-
bles the limit check using the previous/default limit values)
<AbsoluteLevel>
Range:
-256 dBm to 256 dBm
*RST:
-50 dBm
Default unit: dBm
Additional parameters: OFF | ON (disables the limit check | ena-
bles the limit check using the previous/default limit values)
Example:
See
Firmware/Software:
V3.2.70
Options:
R&S CMW-KM502/-KM552 for FDD/TDD
CONFigure:LTE:MEAS<i>:MEValuation:LIMit:ACLR:UTRA<no>:CAGGregation:
OCOMbination
<RelativeLevel>, <AbsoluteLevel>
Defines relative and absolute limits for the ACLR measured in the first or second adja-
cent UTRA channel, depending on <no>.