Remote Control Commands
R&S
®
NRX
279
User Manual 1178.5566.02 ─ 07
13.5.12
NRT
Further information:
●
CALCulate<Measurement>:RELative<DirectionalChannel>:STATe
CALCulate<Measurement>:RELative<DirectionalChannel>:CCDF
......................................279
CALCulate<Measurement>:RELative<DirectionalChannel>:POWer[:MAGNitude]
CALCulate<Measurement>:RELative<DirectionalChannel>:RATio:RCOefficient
CALCulate<Measurement>:RELative<DirectionalChannel>:RATio:RFRatio
CALCulate<Measurement>:RELative<DirectionalChannel>:RATio:RLOSs
........................... 281
CALCulate<Measurement>:RELative<DirectionalChannel>:RATio:SWR
..............................281
CALCulate<Measurement>:RELative<DirectionalChannel>:RATio[:MAGNitude]
[SENSe<Sensor>:]FUNCtion:CONCurrent
........................................................................282
[SENSe<Sensor>:]FUNCtion:OFF:ALL<Channel>
.............................................................282
[SENSe<Sensor>:]FUNCtion:OFF[:FUNC]
........................................................................283
[SENSe<Sensor>:]FUNCtion:STATe?
...............................................................................283
[SENSe<Sensor>:]POWer:REFLection:RANGe:AUTO
.......................................................283
[SENSe<Sensor>:]POWer[:POWer]:RANGe:AUTO
........................................................... 283
[SENSe<Sensor>:]POWer:REFLection:RANGe:LIMit:DETect
............................................. 284
[SENSe<Sensor>:]POWer[:POWer]:RANGe:LIMit:DETect
..................................................284
[SENSe<Sensor>:]POWer:REFLection:RANGe:LIMit[:STATe]
.............................................284
[SENSe<Sensor>:]POWer[:POWer]:RANGe:LIMit[:STATe]
................................................. 284
[SENSe<Sensor>:]POWer:REFLection:RANGe:LOWer
..................................................... 284
[SENSe<Sensor>:]POWer[:POWer]:RANGe:LOWer
..........................................................284
[SENSe<Sensor>:]POWer:REFLection:RANGe[:UPPer]
.................................................... 285
[SENSe<Sensor>:]POWer[:POWer]:RANGe[:UPPer]
.........................................................285
...................................................................................... 285
CALCulate<Measurement>:RELative<DirectionalChannel>:CCDF
<value>
Sets the reference value for the cumulative distribution function (CCDF).
Suffix:
<Measurement>
.
1 to 8
Measurement
<DirectionalChannel> 1 to 2
1 = primary sensor, 2 = secondary sensor or 1 = forward, 2 =
reflection (reverse)
Parameters:
<value>
Range:
0.0 to 100.0
*RST:
50.0
Default unit: pct
Manual operation:
See
"Forward Reference Value, Reflection Reference Value"
on page 55
See
Measurement Settings and Results
www.allice.de
Allice Messtechnik GmbH