background image

OM-RCS-24 SERIES CHEESER STATION

DANFOSS CONTROLLER CODES

DISPLAYED 

ALARM CODE

ALARM

ACTION

Hi

High Temperature Alarm

Inspect door/drawer sealing

Contact service

Lo

Low Temperature Alarm

Contact service

CON

Condenser Temperature 
High Limit 

Clean condenser coil

Inspect coil for any objects 
obstruction hindering airflow 

Contact service

uHi

Line Voltage Too High

Verify voltage of power source, 
to be performed by qualified 
technician

Contact service

uLi

Line Voltage Too Low

Verify voltage of power source, 
to be performed by qualified 
technician

Contact service

LEA

Continuous Compressor 
Runtime  

Inspect door/drawer sealing

Inspect condenser coil, clean if 
necessary

Contact service

E01

S1 Sensor Failure 

Contact service

E02

S2 Sensor Failure 

Contact service

E03

S3 Sensor Failure 

Contact service

E04

S4 Sensor Failure 

Contact service

WEIGH SCALE CODES / ERROR MESSAGES

ERROR

DESCRIPTION

ACTION

(U-----)

The weight is below the 
minimum allowable weight 
reading

Increase the weight or 
decrease the minimum 
allowable weight reading

(O-----)

The weight is above the 
maximum allowable 
weight reading, Warning - 
overloading may damage 
mechanical scale elements

Check the condition of load 
cell connections, check for 
damaged load cell

(ZERO)

(ERROR)

The weight reading is 
beyond the limit set for Zero 
operation 

The operation of the 
<ZERO> key is limited in 
the setup during installation

The indicator cannot be 
Zeroed at this weight

Increase the Zero Range 
(Z.RANGE) or use the <TARE> 
key instead

(STABLE)

(ERROR)

Scale motion has prevented 
a <ZERO>, <TARE> or 
<PRINT> operation from 
occurring on command

Try the operation again once 
the scale is stable

(E0001)

The power supply voltage 
is too low

Check supply

(E0002)

The power supply voltage is 
too high

Check scale/cables

(E0010)

The temperature is outside 
of allowable limits

Check location

(E0020)

Scale build is incorrect, the 
number of graduations has 
been set too low or too high

Fix up scale build

(E0100)

The digital setup 
information has been lost

Re-enter setup

(E0200)

The calibration information 
has been lost

Re-calibrate

(E0300)

All setup information has 
been lost

Enter setup and calibrate

(E0400)

The factory information has 
been lost

Return for service

(E0800)

The EEPROM memory 
storage chip has failed

Return for service

(E2000)

ADC out of range error - 
this may be caused from a 
broken load cell cable

Check BUILD:CABLE setting, 
check load cell cable, wiring, 
etc.

(E4000)

The battery backed RAM 
data has lost data

Re-enter setup

(E8000)

The FLASH program 
memory is incorrect

Return for service

Содержание RCS-24

Страница 1: ...t you do so at once Manufacture Service Questions 888 994 7636 RETAIN THIS MANUAL FOR FUTURE REFERENCE NOTICE Due to a continuous program of product improvement Unified Brands reserves the right to make changes in design and specifications without prior notice NOTICE Please read the entire manual carefully before installation If certain recommended procedures are not followed warranty claims will ...

Страница 2: ...temperature If temperature adjustments are required the control is located on the front panel Confirm that the units is holding the desired temperature 7 If unit has drawers check drawer to ensure the drawer slides freely and fully extents along with seating in the cabinet properly when closed 8 Refer to the front of this manual for serial number location Please record this information in your man...

Страница 3: ...he refrigerated supply bin 2 Determine the location of the Cheeser Station and move into position above image shows the Cheeser Station on the left for left to right operation INSTALLATION OF RCS 24 RACK ASSEMBLY 1 Insert cheese bin inside the refrigerated cold well The bins slanted wall should be placed towards the back 2 Set the rack support assembly in the cold well opening with the front suppo...

Страница 4: ...g on the rail 3 Allow a minimum 45 minutes for your unit to cool down before loading product A uniform frost pattern will appear on side walls and bottom of prep rail area 4 Load the product and proceed with food preparation NOTE Product entering unit must be at 35 F 2 F NIGHTLY SHUT DOWN OF PREP RAIL 1 Remove product from unit at the end of the day s preparation 2 Turn off unit See item 3 under t...

Страница 5: ...repeatedly to return to exit and return to the home screen MAINTENANCE WARNING DO NOT USE SHARP UTENSILS AND OR OBJECTS WARNING DO NOT USE STEEL PADS WIRE BRUSHES SCRAPERS OR CHLORIDE CLEANERS TO CLEAN YOUR STAINLESS STEEL CAUTION DO NOT USE ABRASIVE CLEANING SOLVENTS AND NEVER USE HYDROCHLORIC ACID MURIATIC ACID ON STAINLESS STEEL WARNING DO NOT PRESSURE WASH EQUIPMENT AS DAMAGE TO ELECTRICAL COM...

Страница 6: ...SS STEEL INCLUDE THE FOLLOWING JOB CLEANING AGENT COMMENTS Routine cleaning Soap ammonia detergent Medallion Apply with a sponge or cloth Fingerprints and smears Arcal 20 Lac O Nu Ecoshine Provides a barrier film Stubborn stains and discoloration Cameo Talc Zud First Impression Rub in the direction of the polish lines Greasy and fatty acids blood burnt on foods Easy Off Degrease It Oven Aid Excell...

Страница 7: ...orn or out of place Inspect the gasket for wear and position Incorrect set point Adjust control set point Warm product introduced to cabinet Pre chill product 37ºF Ice on the coil Initiate manual defrost Unit noisy Ice on the coil Initiate manual defrost Unit does not defrost Excessive ice on the coil Initiate manual defrost TROUBLESHOOTING WEIGH SCALE PLATFORM SYMPTOM POSSIBLE CAUSE PROCEDURE Uni...

Страница 8: ...he condition of load cell connections check for damaged load cell ZERO ERROR The weight reading is beyond the limit set for Zero operation The operation of the ZERO key is limited in the setup during installation The indicator cannot be Zeroed at this weight Increase the Zero Range Z RANGE or use the TARE key instead STABLE ERROR Scale motion has prevented a ZERO TARE or PRINT operation from occur...

Страница 9: ...ent set up operations or service please call 888 994 7636 In addition please review the sales terms and conditions set forth below IMPORTANT NOTICE WARRANTIES LIMITATIONS ON WARRANTIES AND LIMITATION OF REMEDIES The following Warranties Limitation on Warranties and Limitation of Remedies are included in the terms of sale for this product Please read this entire warranty and all warranty modificati...

Страница 10: ...OLYPROPYLENE 375 LB CAPACITY 6 2 HD CST1705 CASTER 4 5 IN W BRAKE POLYPROPYLENE 375 LB CAPACITY 7 1 HD RCK1902 RACK SS PREP 18in x 16 25in x 0 25in ROD 8 1 HD PAN1901 PAN CHEESE BIN 19 5 X 24 X 6 DEEP BLACK ABS 9 1 RP PNL2107 PANEL APRON REPLACEMENT PART 10 1 RP DOR2101 CONDENSING UNIT DOOR CHEESER UNIT LT HINGED REPLACEMENT PART 11 1 RP BCK2102 BACK FINISH 24 REPLACEMENT PART 12 4 HD BMP034 BUMPE...

Страница 11: ...EL SCALE INDICATOR W SEE THROUGH WINDOW 21 1 EL SEN1801 SENSOR PHOTOELECTRIC SWITCH 12M CYLINDRICAL DC 10 30V 22 1 PP LBL1956 LABEL SCALE TARE SENSOR 1X3 UNIVERSAL 23 1 RP DSN002 SCREEN DRAIN LARGE 2 24 1 EL SCL2101 SCALE CONTROL DISPLAY BOARD W TERMINATION CONNECTOR 25 1 RP SCL2102 BRACKET WEIGH SCALE DISPLAY BOARD WITH SCREWS 26 1 EL TRN1801 TRANSFORMER 90W CONSTANT VOLTAGE CURRENT CLASS 2 LPF 9...

Страница 12: ...HINGED SHEET METAL ONLY 31 1 HD HDL0103 HANDLE RECESSED DOOR PULL BLACK PLASTIC 32 1 FA NUT0124 NUTSERT 1 4 20 ALUM KPNG RIVNUT 33 1 HD PIN020B PIN 7 16x5 8 W SCW BOLT ONLY J32 X002 34 1 HD PIN020P PIN 7 16x5 8 W SCW PIN ONLY J32 X001 35 1 RP DOR2103 HINGED DOOR MNTING BRACKET HINGED LEFT REPLACEMENT PART 36 7 FA SCW3075T SCREW 10x3 4 THP SMS SS 37 1 FA BLT4062 BOLT 1 4 20x3 4 H H B 18 8 HCYK HEX ...

Страница 13: ...ON 39 1 RP DRN2101 PIPE 1 5 PVC S40 120mm LONG REPLACEMENT PART 40 1 RP DRN2102 BRACKET DRAIN EXTENSION WITH MOUNTING SCREWS 41 1 PB ADP9903 ADAPTOR 1 1 2 PVC FIP X GLUE PVCAF150 42 1 RP DRN2103 PIPE 1 5IN PVC 76mm LONG 43 1 PB ELB2001 ELBOW 1 1 2in PVC 40 45 DEGREE STREET SP x SLIP 44 1 PB VLV0901 VALVE 1 1 2 GATE VALVE PVC SLIP x SLIP 6101 NOT SHOWN ...

Страница 14: ...EPLACEMENT PART 50 2 RP SCL2105 CAP SCALE LOAD CELL BRACKET REPLACEMENT PART 51 2 RP SCL2106 MOUNTING SCALE BRACKET REPLACEMENT PART 52 8 FA BLT0106 BOLT 1 4 20 x 3 4 T H P 18 8 M6KF WITH LIGHT NYLON PATCH 53 2 RP SCL2107 MOUNTING BRACKET RACK WITH PINS REPLACEMENT PART 54 1 HD RCK1904 RACK CHEESER STATION SIZE 18 1 X 18 3 INCH 55 1 HD RCK1902 RACK SS PREP 18in x 16 25in x 0 25in ROD 56 8 RP SCL21...

Страница 15: ...48 66 1 RP HRN2101 WIRE HARNESS SINGLE COMPRESSOR CONDENSING UNIT FAN AND CONTROL 67 1 RP CAP014 CAP TUBE 036 X 96 W DRIER TO INCLUDE 1 042 FILTER DRIER 68 1 RF CMP1801SC START COMPONENTS 1 5HP R290 EMBRACO 115 60 EMX3115U 69 1 RF CMP1801 COMPRESSOR 1 5HP 115V 60HZ R290 EMBRACO EMX3115U 70 4 HD PIN0601 PIN HAIR COTTER WIRE 072D L 1 1 8 ZINC PLATED 71 1 RF CNT1801 PROBE COND COIL YELLOW CFA 290 72 ...

Страница 16: ...16 OM RCS 24 SERIES CHEESER STATION Wiring Diagram CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636 ...

Страница 17: ...17 OM RCS 24 SERIES CHEESER STATION Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By ...

Отзывы: