Warranty Policies (cont.) 

 
Temperature adjustments are not covered under warranty, 
due to the wide 
range of ambient conditions. 
 
To request a warranty approval number, call our Field Service Department at:                  
1-888-994-7636  
 
WHEN OPTIONAL 5 YEAR COMPRESSOR WARRANTY APPLIES 

1.  Provide  reimbursement  to 

an  ASA

  for  the  cost  of  locally  obtained 

replacement  compressor  in  exchange  for  the  return  of  the  defective 
compressor sent back freight prepaid.  Note:  Unified Brands does limit 
amount  of  reimbursement  allowed  and  does  require  bill  from  local 
supply  house  where  compressor  was  obtained  (customer  should  not 
pay servicing agent up front for compressor). 

2.  Provide  repair  at  the  manufacturing  facility  by  requiring  that  the 

defective unit be sent back to Unified Brands freight prepaid.  Perform 
repair  at the  expense  of  Unified  Brands  and ship  the  item  back  to the 
customer freight collect. 

3.  Furnish  a  replacement  compressor  freight  collect  in  exchange  for  the 

return of the defective compressor sent back freight prepaid. 

4.  Furnish  complete  condensing  unit  freight  collect  in  exchange  for  the 

return  of  the  defective  condensing  unit  sent  back  freight  prepaid.  
(Decisions on whether or not to send complete condensing units will be 
made by Unified Brands in-house service technician). 

 
WHEN OPTIONAL LABOR EXTENSION POLICY APPLIES 
Unified Brands will provide reimbursement of labor to an ASA for any customer 
that  has  an  optional  labor  extension  of  our  standard  warranty.    (Contracted 
rates  do  apply)  Unified  Brands  offers  both  1  and  2  year  extensions.    Labor 
extensions begin at the end of our standard warranty and extend out 9 months 
to  1  calendar  year  or  21  months  to  2  calendar  years  from  date  of  purchase.  
Please contact Unified Brands technical service hotline at 1-888-994-7636 for 
details and any question on Authorized Service Agents (ASA). 
 
WHEN EXPORT WARRANTIES APPLY 

1.  Unified  Brands  covers  all  non-electrical  components  under  the  same 

guidelines as our standard domestic policy. 

2.  All  electrical  components  operated  on  60Hz  are  covered  under  our 

standard domestic policy. 

3.  All  electrical  components  operated  on  50Hz  are  covered  for  90  days 

from shipment only. 

4.  Service labor is covered for the first ninety days with authorization from 

the factory prior to service being performed. 
 

Содержание 9215-32-7

Страница 1: ...ds suggests that if you are suspicious of damage to make a notation on the delivery receipt It will be the responsibility of the consignee to file a claim with the carrier We recommend that you do so...

Страница 2: ...2 888 994 7636...

Страница 3: ...nt purchase of Unified Brands food service equipment and welcome to the growing family of satisfied Unified Brands customers Our reputation for superior products is the result of consistent quality cr...

Страница 4: ...ht to make changes in design and specifications without prior notice NOTICE Please read the entire manual carefully before installation If certain recommended procedures are not followed warranty clai...

Страница 5: ...event equipment was shipped to a site other than the final installation site Unified Brands will warranty for a period of three months following installation with proof of starting date up to a maximu...

Страница 6: ...ondensing unit freight collect in exchange for the return of the defective condensing unit sent back freight prepaid Decisions on whether or not to send complete condensing units will be made by Unifi...

Страница 7: ...ormance NOTICE FOOD LOSS IS NOT COVERED UNDER WARRANTY 3 Repairs caused by abuse such as broken glass freight damage or scratches and dents 4 Electrical component failure due to water damage from clea...

Страница 8: ...ndeavor whenever practical to meet dealer s request Freight charges to be collect unless otherwise noted DAMAGES All crating conforms to general motor carrier specifications To avoid concealed damage...

Страница 9: ...ctory for rate INSTALLATION Equipment installation is the responsibility of the dealer and or their customer Unified Brands requires all equipment to be professionally installed PENALTY CLAUSES Dealer...

Страница 10: ...SHELVES CU FT HP VOLT AMPS NEMA SHIP WT 9215 32 7 48 33 36 2 18 11 58 9 5 1 4 115 60 1 6 5 5 15P 325 9205 32 7 60 33 36 2 24 16 21 13 5 1 4 115 60 1 6 5 5 15P 370 9235 32 7 72 33 36 2 27 20 01 20 1 4...

Страница 11: ...d dented or rubbing together 2 Check that the condenser and evaporator fans rotate freely without striking any stationary members 3 Unit must be properly leveled check all legs or casters to ensure th...

Страница 12: ...ge 3 for location NOTE It is important that a voltage reading be made at the compressor motor electrical connections while the unit is in operation to verify the correct voltage required by the compre...

Страница 13: ...eached Before making temperature adjustments A Make sure that you are allowing adequate time for the cabinet temperature to equalize When initially started or when first loaded it can take a long time...

Страница 14: ...e mounted to the cabinet with two screws on the upper hinge and a hinge pin on the bottom To adjust the door first open it to 90 and loosen the two screws enough to reposition the door Once reposition...

Страница 15: ...asis with a solution of warm water and a mild detergent to extend gasket life 5 Lubricate door hinges with lithium grease NOTE DO NOT USE SHARP UTENSILS AND OR OBJECTS RECOMMENDED CLEANERS FOR YOUR ST...

Страница 16: ...er this service at very reasonable rates to allow you the time you need to run your business along with the peace of mind that all your equipment will last throughout its expected life These services...

Страница 17: ...Unifiedbrands net 17 Electrical Diagram...

Страница 18: ...room lower 5 Defrost evaporator 6 Replace door gasket 7 Check door seal Unit not cold enough 1 Temperature control set too high 2 Temperature control faulty 3 Condenser coil dirty 4 Refrigerant leaki...

Страница 19: ...your unit cool poorly run constantly or even stop completely if the compressor overheats Clean coil using a vacuum cleaner with wand attachment If the coil is greasy wash it with a solution of warm w...

Страница 20: ...or binds replace it If any damage to the blade is observed unscrew the retaining nut that holds the blade to the motor shaft and pull the blade off the shaft Install a new fan blade replacing any wash...

Страница 21: ...X1 place the probes on terminals S and M The multimeter needle should sweep across the scale indicating full continuity Remove the probe from terminal M and place it on the side terminal marked L The...

Страница 22: ...be against the metal housing of the compressor if necessary scrape off a small amount of paint to ensure contact with bare metal Place the other probe on each of the three terminals in turn If any of...

Страница 23: ...INGE RIGHT RP HNG9901 RP HNG9901 RP HNG9901 RP HNG9901 D2 GASKET IN GSK1025 IN GSK1020 IN GSK1025 IN GSK1030 GASKET N A N A IN GSK1020 N A D3 REF DOOR ASSEMBLY LEFT RP DOR104 RP DOR102 RP DOR104 RP DO...

Страница 24: ...B5 CONDENSER SHROUD T07 1028C D17 T07 1028C D17 T07 1028E D17 T07 1028D D17 B6 CONDENSING UNIT RF CON1406 RF CON1406 RF CON1406 RF CON1406 CONDENSING UNIT CLIPS T07 0500 T07 0500 T07 0500 T07 0500 RE...

Страница 25: ...CLP100 HD CLP100 S2 SHELF SUPPORT BRACKET T07 1501A T07 1501A T07 1501A T07 1501A S3 THERMOMETER HD THR100 HD THR100 HR THR100 HD THR100 S4 WIRE SHELF HD SHL060 HD SHL015 HD SHL060 HD SHL105 WIRE SHEL...

Страница 26: ...103 RP SHD0104 RP SHD0103 RP SHD0104 RP SHD0103 RP SHD0104 RP SHD0103 RP SHD0104 E6 EVAP COIL RF COI125 RF COI125 RF COI125 RF COI125 E7 CONTROL HD CNT1401 HD CNT1401 HD CNT1401 HD CNT1401 E7 CONTROL...

Страница 27: ...Unifiedbrands net 27 NOTES...

Отзывы: