OM-8000D SERIES PREP TABLES

OPERATION

EASY MORNING STARTUP

1.  Turn on the condiment rail by pressing and holding the rail control power button until the LED 

display turns on.  Let the unit cool for a minimum of 45 minutes.

2.  Load the product pans as needed. The loaded product should be 36ºF or below for best results.

FOOD-SAFE OPERATIONS

1.  Closing the lids on the condiment rail during non-peak hours will extend the holding time of   

food product.

2.  The frost above the product pans may come and go during the day -- this is normal. The unit 

automatically regulates the rail temperature to keep your food safe and fresh.

NIGHTLY ENERGY-SAVING SHUTDOWN

1.  Remove the product pans from the upper rail and place in the conveniently located base storage, 

or any other suitable cold-storage area.

2.  Turn off the condiment rail by pressing and holding the rail control power button until the LED 

display turns off.

3.  Remove any food "spillage" or debris, rinse and sanitize rail removing any excess water through 

the drain system located at the end of the unit into a suitable water tight container.

4.  Close the rail lid to minimize dust and debris contamination.
5.  The base will continue to operate normally and may be used for overnight storage.

This equipment is intended for use in rooms having an ambient temperature of 30ºC/86ºF or less. 
(NSF labeling requirement). Contact factory for Spanish instructions at 888.994.7636. 

MECHANICAL COMPARTMENT

WARNING:  BASE EVAPORATOR FANS ARE ALWAYS IN OPERATION WHEN THE UNIT IS 

ENERGIZED.  DISCONNECT POWER TO THE UNIT PRIOR TO PERFORMING 

MAINTENANCE.

1.  To power on the base, press and hold the base control power button until the 

LED display turns on.   To power on the rail, press and hold the rail control 
power button until the LED display turns on. The power controls are located 
above the louver panel. Both upper and lower rail are controlled by controller 
marked Rail.

2.  To power off the base press and hold the base control power button until the 

LED display turns off. To power off the rail press and hold the rail control power 
button until the LED display turns off. The power controls are located above the 
louver panel.

3.  The drain valve for the upper 

rail is found behind the vented 
door. The rail may be drained by 
placing a pan under the drain 
valve and opening the valve. 
(See Evening Shut Down of Prep 
Rail).

MORNING STARTUP OF PREP RAIL

1.  Unit cleaning may be performed at this time.
2.  Turn on unit. See item 2 under the Mechanical Compartment section above for 

powering on the rail.

3.  Allow a minimum 45 minutes for your unit to cool down before loading product. 

A uniform frost pattern will appear on side walls and bottom of prep rail area.

4.  Load the product and proceed with food preparation. NOTE: Product entering 

unit must be at 35°F +/- 2°F.

EVENING SHUT DOWN OF PREP RAIL

1.  Remove product from unit at the end of the day’s preparation.
2.  Turn off unit.  See item 3 under the Mechanical Compartment section above for 

powering on the rail. 

3.  Unit cleaning may be performed at this time if the frost has melted off the 

surface.

4.  Once defrosted, the rail drain may be opened to remove any water that has 

resulted from the defrosting procedure.

WARNING:  IT IS RECOMMENDED TO ONLY MAKE CHANGES OF 2 DEGREE INCREMENTS 

AT A TIME. ALLOW FOR THE UNIT TO OPERATE 24 HOURS BETWEEN 

ADJUSTMENTS. IF THE 2 DEGREE ADJUSTMENT IS NOT ENOUGH ANOTHER 

ADJUSTMENT CAN BE MADE. IF THE SETTINGS NEED TO GO ABOVE OR 

BELOW THIS POINT THERE MAY BE OTHER CONTRIBUTING FACTORS AS 

TO THE CAUSE OF THE TEMPERATURE VARIANCES, PLEASE CONTACT THE 

FACTORY AT 1-800-621-8560.

AMBIENT CONDITIONS

Unit is designed for normal operating temperatures between 70° F (21°C) - 86°F 
(32°C). Operating outside of those temperatures may cause premature product 
wear or failure.
Unified Brands has attempted to preset the temperature control to ensure that 
your unit runs at an optimum temperature, but due to varying ambient conditions, 
including elevation, food type and your type of operation, you may need to alter 
this temperature using control adjustment until desired temperature is reached. 

DANFOSS CONTROLLER OPERATION

LED

FUNCTION

Compressor energized & Evaporator fan de-energized

Defrost in progress

Fans delay after defrost completion

Evaporator fan energize

An alarm is occurring

ºC / ºF

Temperature unit

POWER ON / OFF

MANUAL DEFROST

CHANGE SET POINT

POWER ON / OFF: 

Press and hold the power button until LED display turns On / Off

MANUAL DEFROST: 

Press and hold “Defrost” Button

CHANGE SET POINT:  

To raise temperature

1.  Press and hold “ ” to access set point. 
2.  When set point start flashing, Press “ ” to adjust set point.
3.  After 30 seconds, the display automatically reverts to showing the current 

temperature. 

CHANGE SET POINT:

  To lower temperature

1.  Press and hold “v” to access set point.
2.  When set point start flashing, Press “v” to adjust set point.
3.  After 30 seconds, the display automatically reverts to showing the current 

temperature.

Содержание 8000D-290 Series

Страница 1: ...TIFY CARRIER OF DAMAGE AT ONCE It is the responsibility of the consignee to inspect the container upon receipt of same and to determine the possibility of any damage including concealed damage Unified...

Страница 2: ...n exhaust from the machine compartment register 3 Clearance This units clearance requirements are 0 in at the top 0 in at the rear and 0 in at each side INSTALLATION CHECKLIST After the final location...

Страница 3: ...STARTUP OF PREP RAIL 1 Unit cleaning may be performed at this time 2 Turn on unit See item 2 under the Mechanical Compartment section above for powering on the rail 3 Allow a minimum 45 minutes for yo...

Страница 4: ...ot use bleach for cleaning gaskets Bleach will cause the gaskets to become brittle and not reach their normal life expectancy 2 Clean and disinfect rail drains with a solution of warm water and mild d...

Страница 5: ...e Disconnect the hoses Remove line taps Greasy and fatty acids blood burnt on foods Easy Off Degrease It Oven Aid Excellent removal on all finishes Grease and Oil Any good commercial detergent Apply w...

Страница 6: ...RT DESCRIPTION 1 RP CNT1902 CONTROLLER PROGRAMMED TOP RAIL X X X 1A RP CNT1902 CONTROLLER PROGRAMMED BOTTOM RAIL X X X 1B PR CNT1807 CONTROLLER PROGRAMMED BASE X X X 2 RF CNT1602 SENSOR COIL X X X 3 R...

Страница 7: ...D CTH9901 LOUVER MAGNET X X X 4 RP SHD1901 SHROUD COIL X X X 4A RP SHD1902 SHROUD COIL 5 RP PNL1803 COVER ACCCESS SIDE CMPR L OR R X X X 6 HD SHL180 SHELF 22 X 25 X X 6A HD SHL060 SHELF 19 1 8 X 25 1...

Страница 8: ...s List FAN ASSIST CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636 8148D 290 8272D 290 8396D 290 ITEM SERVICE PART DESCRIPTION 1 RP FAN1801 FAN ASSIST ASSY X 2 RF FAN1401 FAN ASSIST MOTOR X 3 RF FAN070...

Страница 9: ...S X X X 3 RP CAP1802 CAP TUBE BOTTOM RAIL X X X 4 RF FAN0601 CONDENSER FAN X X X 5 HD GRD1610 FAN GUARD X X X 6 RF FLT251 FILTER DRIER 1 4 DBL INLET X X X 7 RF ACM1701 ACCUMULATOR X X X 8 RP MNT1803 C...

Страница 10: ...ATOR COIL X X X 2 RP CAP1804 CAP TUBE BASE X X 2A RP CAP1803 CAP TUBE BASE X 3 RF FAN1401 FAN EVAPORATORS X X X 4 RP DRP107 EVAPORATOR DRAIN PAN X X X 5 RP PNL107 290 SIDE COIL 8000N COMMON X X X 6 RP...

Страница 11: ...3 DOOR HINGED LEFT 24 X X 1C RF DOR0322 DOOR HINGED RIGHT 24 X X 1D RF DOR0324 DOOR HINGED LEFT 27 X X 1E RF DOR0325 DOOR HINGED RIGHT 27 X X 2 IN GSK9902 GASKET 18 5 X 24 5 PUSH IN 2A IN GSK1025 GASK...

Страница 12: ...A DRAWER CARTRIDGE 24 X X 2B RP MOD029A DRAWER CARTRIDGE 27 X X 3 RF FRT9903 DRAWER FRONT 21 3A RF FRT9904 DRAWER FRONT 24 X X 3B RF FRT9905 DRAWER FRONT 27 X X 4 RP FRM0301 DRAWER FRAME 21 4A RP FRM0...

Страница 13: ...2 PVC FAMALE X X X 2 PB TBG1801 TUBING 1 VINYL BLACK X X X 3 HD CLM1801 CLAMP 1 OETIKER X X X 4 HD DRN1702 DRAIN ABS GRAY 1 375 1 00 NPS X 2 875 LG W NUT WASHER X X X 5 PB ADP1802 ADAPTOR 1 X 1 ST IN...

Страница 14: ...HD ROD200 HOOD COVER ROD W DOUBLE BEND X X X 3 HD PIN107 PIN THREADED SOUTHCO X X X 4 RP BAR1325 BAR ADAPTER 12 75 X 7 8 8000N TPT_1AB_1 X X X 5 RP DSN001 DRAIN SCREEN 2 X X X 6 HD PIN001 PIN KEY PAN...

Страница 15: ...15 OM 8000D SERIES PREP TABLES Wiring Diagram...

Страница 16: ...16 OM 8000D SERIES PREP TABLES Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Отзывы: