OM-8000D SERIES PREP TABLES

INSTALLATION

CAUTION:  THIS UNIT CONTAINS R290 FLAMMABLE REFRIGERANT.  USE CAUTION 

WHEN HANDLING MOVING AND USE OF THE REFRIGERATOR OR FREEZER.  

AVOID DAMAGING THE REFRIGERANT TUBING OR INCREASE THE RISK OF A 

LEAK. 

WARNING:  FAILURE TO FOLLOW INSTALLATION GUIDELINES AND 

RECOMMENDATIONS MAY VOID THE WARRANTY ON YOUR UNIT.

WARNING:  IT IS IMPORTANT THAT YOUR UNIT HAS ITS OWN DEDICATED LINE. 

CONDENSING UNITS ARE DESIGNED TO OPERATE WITH A VOLTAGE 

FLUCTUATION OF PLUS OR MINUS 10% OF THE VOLTAGE INDICATED ON 

THE UNIT DATA TAG. BURN OUT OF A CONDENSING UNIT DUE TO EXCEEDING 

VOLTAGE LIMITS WILL VOID THE WARRANTY.

 

THE DANFOSS CONTROLLER HAS LOW VOLTAGE PROTECTION AND WILL 

NOT OUTPUT VOLTAGE TO THE COMPRESSOR IF VOLTAGE IS LESS THAN 
104V.

WARNING:  IT IS IMPORTANT THAT A VOLTAGE READING BE MADE AT THE COMPRESSOR 

MOTOR ELECTRICAL CONNECTIONS, WHILE THE UNIT IS IN OPERATION 

TO VERIFY THE CORRECT VOLTAGE REQUIRED BY THE COMPRESSOR IS 

BEING SUPPLIED.  LOW OR HIGH VOLTAGE CAN DETRIMENTALLY AFFECT 
OPERATION AND THEREBY VOID ITS WARRANTY.

WARNING:  EVAPORATOR FANS RUN CONTINUOUSLY WHILE THE BASE IS POWERED ON.
WARNING:  THIS UNIT IS INTENDED FOR USE IN LABORATORIES IN COMMERCIAL, 

INDUSTRIAL, OR INSTITUTIONAL OCCUPANCIES AS DEFINED IN THE 

SAFETY STANDARD FOR REFRIGERATION SYSTEMS, ASHRAE 15. 

SELECTING A LOCATION FOR YOUR NEW UNIT

The following conditions should be considered when selecting a location for 
your unit:
1. 

Floor Load: 

 The area on which the unit will rest must be level, free of vibration, 

and suitably strong enough to support the combined weights of the unit plus 
the maximum product load weight. All casters must be in contact with the floor 
to support the weight. Casters may require shims in order for the caster to be 
in contact with the floor. NOTE:  If there is a question pertaining to weight load 
limits, consult the factory at 1-888-994-7636.

2. 

Ventilation:

  The air cooled self contained unit requires a sufficient amount 

of cool clean air.  Avoid surrounding your unit around other heat generating 
equipment and out of direct sunlight.  Also, avoid locating in an unheated 
room or where the room temperature may drop below 70° F (21°C) or above 
86°F (32°C). Do not place any object that can block the ventilation exhaust 
from the machine compartment register.

3. 

Clearance:

  This units clearance requirements are 0 in. at the top, 0 in. at the 

rear and 0 in. at each side. 

INSTALLATION CHECKLIST

After the final location has been determined, refer to the following checklist prior 
to start-up:
1.  Check all exposed refrigeration lines to ensure that they are not kinked, 

dented, or rubbing together or rubbing against any steel.

2.  Check all visible components for any potential damage.
3.  Check that the condenser and evaporator fans rotate freely without striking 

any stationary members.

4.  Unit must be property leveled; Check all legs or casters ensure they all are 

in contact with the floor while maintaining a level work surface.  Adjusting 
bullet feet height or shimming casters may be necessary if the floor is not 
level.  NOTE:  Damage to equipment may result if not followed.  Unified 
Brands is not responsible for damage to equipment if improperly installed.

5.  Plug unit into power source.  Unit will come on.  If unit does not turn on, refer 

to controller operation section of this manual to manually turn on the unit.

6.  Allow unit time to cool down to holding temperature. If temperature 

adjustments are required, the control is located on the front panel.  Confirm 
that the units is holding the desired temperature.

7.  If unit has drawers, check drawer to ensure the drawer slides freely and fully 

extents along with seating in the cabinet properly when closed.

8.  Refer to the front of this manual for serial number location.  Please record 

this information in your manual on page 1 now.  It will be necessary when 
ordering replacement parts or requesting warranty service.

9.  Allow your unit to operate for approximately 45 minutes before putting in 

food in the rail.  Allow 2 hours for base of the unit to cool down to storage 
temperature, prior to loading product. NOTE:  All motors are oiled and sealed.

ELECTRICAL SUPPLY

The wiring should be done by a qualified electrician in accordance with local 
electrical codes.  A properly wired and grounded outlet will assure proper 
operation.  Please consult the data tag attached to the compressor to ascertain 
the correct electrical requirements.  Supply voltage and amperage requirements 
are located on the serial number tag located on the rear interior wall. 

IMPORTANT - READ FIRST - IMPORTANT

INTERIOR EVAPORATOR COVER

EXTERIOR OF UNIT

NEAR EXPOSED REFRIGERANT TUBING

NEAR MACHINE COMPARTMENT AND NAMEPLATE

Содержание 8000D-290 Series

Страница 1: ...TIFY CARRIER OF DAMAGE AT ONCE It is the responsibility of the consignee to inspect the container upon receipt of same and to determine the possibility of any damage including concealed damage Unified...

Страница 2: ...n exhaust from the machine compartment register 3 Clearance This units clearance requirements are 0 in at the top 0 in at the rear and 0 in at each side INSTALLATION CHECKLIST After the final location...

Страница 3: ...STARTUP OF PREP RAIL 1 Unit cleaning may be performed at this time 2 Turn on unit See item 2 under the Mechanical Compartment section above for powering on the rail 3 Allow a minimum 45 minutes for yo...

Страница 4: ...ot use bleach for cleaning gaskets Bleach will cause the gaskets to become brittle and not reach their normal life expectancy 2 Clean and disinfect rail drains with a solution of warm water and mild d...

Страница 5: ...e Disconnect the hoses Remove line taps Greasy and fatty acids blood burnt on foods Easy Off Degrease It Oven Aid Excellent removal on all finishes Grease and Oil Any good commercial detergent Apply w...

Страница 6: ...RT DESCRIPTION 1 RP CNT1902 CONTROLLER PROGRAMMED TOP RAIL X X X 1A RP CNT1902 CONTROLLER PROGRAMMED BOTTOM RAIL X X X 1B PR CNT1807 CONTROLLER PROGRAMMED BASE X X X 2 RF CNT1602 SENSOR COIL X X X 3 R...

Страница 7: ...D CTH9901 LOUVER MAGNET X X X 4 RP SHD1901 SHROUD COIL X X X 4A RP SHD1902 SHROUD COIL 5 RP PNL1803 COVER ACCCESS SIDE CMPR L OR R X X X 6 HD SHL180 SHELF 22 X 25 X X 6A HD SHL060 SHELF 19 1 8 X 25 1...

Страница 8: ...s List FAN ASSIST CALL FACTORY FOR REPLACEMENT PARTS 888 994 7636 8148D 290 8272D 290 8396D 290 ITEM SERVICE PART DESCRIPTION 1 RP FAN1801 FAN ASSIST ASSY X 2 RF FAN1401 FAN ASSIST MOTOR X 3 RF FAN070...

Страница 9: ...S X X X 3 RP CAP1802 CAP TUBE BOTTOM RAIL X X X 4 RF FAN0601 CONDENSER FAN X X X 5 HD GRD1610 FAN GUARD X X X 6 RF FLT251 FILTER DRIER 1 4 DBL INLET X X X 7 RF ACM1701 ACCUMULATOR X X X 8 RP MNT1803 C...

Страница 10: ...ATOR COIL X X X 2 RP CAP1804 CAP TUBE BASE X X 2A RP CAP1803 CAP TUBE BASE X 3 RF FAN1401 FAN EVAPORATORS X X X 4 RP DRP107 EVAPORATOR DRAIN PAN X X X 5 RP PNL107 290 SIDE COIL 8000N COMMON X X X 6 RP...

Страница 11: ...3 DOOR HINGED LEFT 24 X X 1C RF DOR0322 DOOR HINGED RIGHT 24 X X 1D RF DOR0324 DOOR HINGED LEFT 27 X X 1E RF DOR0325 DOOR HINGED RIGHT 27 X X 2 IN GSK9902 GASKET 18 5 X 24 5 PUSH IN 2A IN GSK1025 GASK...

Страница 12: ...A DRAWER CARTRIDGE 24 X X 2B RP MOD029A DRAWER CARTRIDGE 27 X X 3 RF FRT9903 DRAWER FRONT 21 3A RF FRT9904 DRAWER FRONT 24 X X 3B RF FRT9905 DRAWER FRONT 27 X X 4 RP FRM0301 DRAWER FRAME 21 4A RP FRM0...

Страница 13: ...2 PVC FAMALE X X X 2 PB TBG1801 TUBING 1 VINYL BLACK X X X 3 HD CLM1801 CLAMP 1 OETIKER X X X 4 HD DRN1702 DRAIN ABS GRAY 1 375 1 00 NPS X 2 875 LG W NUT WASHER X X X 5 PB ADP1802 ADAPTOR 1 X 1 ST IN...

Страница 14: ...HD ROD200 HOOD COVER ROD W DOUBLE BEND X X X 3 HD PIN107 PIN THREADED SOUTHCO X X X 4 RP BAR1325 BAR ADAPTER 12 75 X 7 8 8000N TPT_1AB_1 X X X 5 RP DSN001 DRAIN SCREEN 2 X X X 6 HD PIN001 PIN KEY PAN...

Страница 15: ...15 OM 8000D SERIES PREP TABLES Wiring Diagram...

Страница 16: ...16 OM 8000D SERIES PREP TABLES Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Отзывы:

Похожие инструкции для 8000D-290 Series