IMPORTANT  SAFETY REQUIREMENTS BY UL STANDARDS 

Prior to installation, the following must 

be observed: (per UL325.56.8.4) 

a) Install the gate operator only when:

1) The operator is appropriate for the construc­

tion of the gate and the usage Class of the

gate,

2) All openings of a horizontal slide gate are

guarded or screened from the bottom of the 

gate to a minimum of 4 feet (1

.

22 m

above 

tne ground to prevent a 2 

1/

4 inch 

(

57.2 mm) 

diameter sphere from passing through the 

openings anywhere in the gale

and 

i

n that 

portion of the adjacent fence that the gate 

covers in the open position, 

3) All exposed pinch points are eliminated or

guarded

and

4)

G

uarding is supplied for exposed rollers.

b) The operator is intended for installation only on

gates used for vehicles.  Pedestrians must be

supplied with a separate access opening.  The

pedestrian access opening shall be designed to

promote pedestrian usage.  Locate the gate

such that persons will not come in contact with

the vehicular gate during the entire path of travel

of the vehicular gate.

c) The gate must be installed in a location so that

enough clearance is supplied between the gate

and adjacent structures when opeing and 

closing to reduce the risk of entrapment. 

Swinging gates shall not open into public access 

areas. 

d) The gate must be properly installed and work

free

l

y in both directions prior to the insallation of

the gate operator.  Do not over-tighten the 

operator clutch or pressure relief valve to com 

pensate for a damaged gate. 

e) For gate operators utilizing Type D protection:

1 ) 

T

he gate operator controls must be placed so

that the user has full view of the gate area

when the gate is mov

i

ng

2) The p

l

acard as required by 58.1.6 shall be

placed adjacent to the controls,

3)An automatic closing device (such as a timer,

loop sensor, or similar device) shall not be 

employed, and 

4 )No other activation device shall be connected. 

f) Controls intended for user activation must be

located at least six feet (6') away from any

moving part of the gate and where the user is 

prevented from reaching over, under, around or 

through the gate to operate the controls. 

Outdoor or easily accessible controls shall have 

a security feature to prevent unauthorized use. 

g) The stop and/or reset button must be located in

the line-of-sight of the gate. Activation of the

reset control shall not cause the operator to

start.

h)A minimum of two (2) WARNING SIGNS shall be

installed, one on each side of the gate where

easily visible. 

i) For gate ope

r

ators ut

i

lizing a non-contact sensor

in accordance with UL 31.1

.

1

:

1) See instructions on the placement of non­

contact sensors for each Type of application.

2) Care shall be exercised to reduce the.risk of

nuisance tripping, such as when a vehicle,

trips the sensor while the gate is still moving,

and

3) One or more non-contact sensors shall be

located where the risk of entrapment or

obstruction exists, such as the perimeter

reachable by a moving gate or ba

r

r

i

er.

j) For a gate operator utilizing a contact sensor in

accordance with 31.1.1:

1) One or more contact sensors shall be

located where the risk of entrapment or

obstruction exists, such as at the leading

ed9e, trailing edge

and postmounted both

inside and outside of a vehicular horizontal

slide gale.

2) One or more contact sensors shall be

located at the bottom edge of a vehicular

vertical lift gate.

3) One or more contact sensors shall be

located at the pinch point of a vehicular

vertical pivot gale.

4) A hardwired contact sensor shall be localed

and its wiring arranged so that the communi­

cation between the sensor and the gate

operator is not subjected to mechanical

damage.

5) A wireless contact sensor such as one that 

transmits radio frequency (RF) signals to the 

gale operator for entrapment protect

i

on. func­

t

i

o

n

s shall be located where t

h

e transmission

of the signals are not obstructed or impeded 

by building structures, natural landscaping or 

similar obstruction. A wireless contact 

sensor shall function under the intended 

end-use conditions. 

6) One or more contact sensors shall be

located on the inside and outside leading

edge of a sw

i

ng gate. Additionally, if the

bottom edge of a swing gate is greater than

6 inches ('f52 mm) above the ground at any

point in its arc of travel, one or more contact

sensors shall be located on the bottom edge.

7) One or more contact sensors shall be

located at the bottom edge of a vertical

barrier (arm).

www.RamsetStore.com  |  (800) 878-7829  |  [email protected]

Содержание RAM 300

Страница 1: ...www RamsetStore com 800 878 7829 Sales RamsetStore com...

Страница 2: ...ence or appropriate WARNING training with gate operators IMPORTANT SAFETY REQUIREMENTS INSTRUCTIONS WARNING To reduce the risk ofinjury 01 death I READ FOLLOWALL INSTRUCTIONS 2 Never let children oper...

Страница 3: ...TRIC EYE OR LOOP DETECTOR CHECK THE E R D SENSITIVITY MAKE SURE THAT ALL AREAS AROUND THE GATE ARE SAFE AND SECURE SUCH AS THE FRONT REAR AND TRAVEL AREA COMMUNICATE WITH THE END USER INSTRUCT THE END...

Страница 4: ...ate the controls Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use g The stop and or reset button must be located in the line of sight of the gate Activat...

Страница 5: ...s vehicular gate operator Class m A vehicular gate operator or system intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to s...

Страница 6: ...Lubricated by oil bath gives smooth and quit operation CHASSIS 3 16 hot rolled steel FINISH Gold zinc plated to inhibit corrosion POWER FAILURE RELEASE Exclusive foot pedal release OVERALL DIMENSIONS...

Страница 7: ...given in illustration 3 Level top edge of form 4 Set reinforcing bars and wire mesh 5 Allow pad to cure for 48 hours and remove forms Outside Property Inside Property j 0 Gate Closed See Fig 5 6 or8...

Страница 8: ...to be tightened to a minimum of 40 lbs above weight of gate in order to avoid slipping lii Miil Gate travel is adjusted by loosening the limit Cams and positioning them until proper gate travel has be...

Страница 9: ...ES FROM 14 TO 18 IN LENGTH 8 42 34 OPERATOR PIVOT SHAFTCENTER 50 32 314 76 r h H1hii 32 SHORTARM DIM LONGARMDUA SPACE REQUIRED FOR A STANDARD GATE IN THE OPEN POSITION l i L liH iiil www RamsetStore c...

Страница 10: ...PIVOTSHAFTCENTER 24 1 4 44 1 4 24 _ o N GAR M o IM _ MINIMUM SPACE REQUIRED FOR COMPACT INSTALLATION 20 minimum space required between open gate and wall for this compact installation 20 10 lihl Hil...

Страница 11: ...rosses loop area Photoelectric Safety Sensor Photo Eye prevents the gate from closing when any object interrupts the beam Outside Property Operator Factory pre set for LH operation __ INSTALL A SAFETY...

Страница 12: ...sing this button will cause the gate to stop moving Closing Pressing this button will cause the gate to close Reset E R o Board Push all three pushbuttons for approximately 5 seconds All three L E D s...

Страница 13: ...slave gates that work together should be set lo the same Dip Switch A 4 112 HP E R D address Side gates use the address setup Sw 4 5 Function Sw Function OFF Most sensitive ON Setting for stronger E R...

Страница 14: ...ommand and reverse with a second command Dip Switch c 4 ONE PASS Sw Function OFF Normal Operation fully opens and closes ON One pass mode The gate will open until the reversing IOOP is initially activ...

Страница 15: ...flector Safety Sensor Photo Eye Rev Loop P Safety Sensor Reflector Photo Eye for Backplane Radio Terminal Slrlp Electric Motor 120VAC or 220VAC hihl iiill In order to use COMMON and ST remove jumper 2...

Страница 16: ...is cleared the operator will resume normal operation If triggered twice before reaching a limit switch the alarm will sound for 6 minutes and the control board will not RAMSET accept any commands Aft...

Страница 17: ...er Stave ___ _ Master Slave Plug Synchronizes movement between two gates 3WYes A B and Common Battery Back up System plug Standard Connections Reven e Loop Fite Box Exit Loop Pnamom L oop Rad o EdgO S...

Страница 18: ...Inputs 1 2 Reverse 3 4 Exit 5 6 Phantom Use with ILD 24 Loop wires should be connected to this plug JP4 JP5 JP8 Reverse Exit Phantom Sensor Used with the Ramset ILD 24 plug in loop detector The Loop w...

Страница 19: ...25 10 3 6 70 74 71 72 2 69 55 57 63 4 28 26 85 77 79 84 83 81 82 23 75 73 54 5 16 30 29 8 36 37 9 53 35 24 11 12 13 31 34 41 39 32 33 15 15 42 40 14 27 7 76 78 78 84 52 www RamsetStore com 800 878 782...

Страница 20: ...0 50 41 Wire Harness Outlet R300 1 19 800 50 90 Wire Harness Foot Pedal R300 1 20 800 51 03 Wire Harness Limit Switches R300 1 21 800 51 22 Wire Harness Radio terminal R300 1 22 800 51 23 Wire Harness...

Страница 21: ...75 05 Access Door Assembly 1 56 800 16 00 Access Door Stainless Steel R300 1 57 800 18 00 Key Access Door 313 2 58 800 18 01 Lock Assembly 313 Key 1 59 800 32 40 Screw Machine 6 32 x 3 8 flat 2 60 80...

Страница 22: ...on Washer Torque Limited 3 R300 1 80 800 34 22 Set Screw 1 4 20 x 3 8 2 81 800 36 20 Bolt Hex Head 3 8 16 x 1 3 82 800 46 30 Bushing UHMW Sprocket ID 1 3 4 OD 2 R300 1 83 800 58 02 Arbor Nut Torque Li...

Страница 23: ...the area of a moving gate 4 All opening devices such as a keypad cardreader should not be installed close to the gate where the gate could possibly cause injury 5 Use warning signs attached on both s...

Страница 24: ...e area of a moving gate Use the emergency release only when the gate is not moving Make sure when using the foot releaseorhand crank the circuit breaker for the operator is turned off Have the technic...

Страница 25: ...gnetic Lock Battery Back up System Heavy Duty Industrial Uphill Hinges Uphill Arms To be used under uneven conditions Radio Receiver RAMSET LCD KP Liquid Crystal Display Key1 ad RAMSET ILD 24S Plug in...

Отзывы: