Frame
Boss
™
Instruction Manual
Site Preparation
• Ensure tool is ready for use.
• Clear people from local area.
• Erect warning signs.
• Check the area is safe for the use of P.A. Tools,
i.e. free from inflammable gases, explosive
materials etc.
• Check that the material to be fixed into is
suitable for use with a P.A. Tool.
• Make sure the correct Personal Protective
Equipment (PPE) is being worn by all those
close by.
Tool Inspection
Every Powder Actuated (P.A.) hand-held fastening
tool should be dismantled and examined for
defects by an authorised operator prior to use.
• The straightness of the piston - if it is not
straight, replace it.
• The piston buffer - replace if it is worn or less
than 4mm thick.
7.
Using the supplied wire brushes, thoroughly
clean all internal and external steel surfaces of
any carbon buildup.
8.
Lightly oil the internal steel components with
Ramset™ P.A. lubricant (PA9316) and then
wipe off any excess oil.
re-assembly is the reverse of disasssembly
1.
Position the barrel’s groove at the top.
2.
Insert the barrel’s assembly into the main
housing and screw the knurled collar by hand.
(Do not over tighten).
3.
After re-assembly check that the barrel slides
properly in the handle.
4.
Slide the buffer onto the piston
5.
Slide the piston return spring onto the piston.
6.
Insert the piston assembly into the barrel.
7.
Screw the magazine or the fastener guide onto
the barrel.
8.
Without any power loads or fasteners, test the
tool for correct function by cocking the tool
and depressing the trigger. If this test does not
work, do no attempt to use the tool.
14