Fastener Setting
For flush timber fixing (i.e. no washer), the fastener
is correctly set when the head of the fastener is
flush with the surface of the timber.
When fixing to thinner materials the fastener is
correctly set when the under side of the fastener
head is in contact with the material surface with
only minor deformation of the material.
The fastener is over driven if:
• the head is excessively embedded into the
fixing material, or
• the shank of the fastener is damaged or broken
during driving.
If the fastener is over driven, reduce power by
selecting a lower strength power load or adjusting
the power setting (if applicable).
If the fastener is under driven by a tool with power
adjustment, increase the power by increasing the
power setting until a suitable fixing is achieved. If
the maximum setting is reached, move the wheel
back to the minimum position and use the next
strength power load and repeat the process.
If the fastener is under driven by tools without
power adjustment, increase the power by using
the next strength power load.
Pin selection and correct setting
The correct selection and setting of the drive pin
is critical with all low velocity tools to ensure a
secure fixing and long tool life.
This illustration shows a threaded stud and