background image

 

Appendix: WM-CUB wiring diagrams  

Mains switching  

The WM-CUB is most commonly used with “mains switching blinds”.  The six way terminal 
block is fed with permanent mains and has two switched mains outputs. A three core and 
earth cable should be run from the WM-CUB to the blind.  
 

24V Polarity switching 
 

The WM-CUB can also be used to control 24V polarity switching blinds. In this case a 
separate 24V power supply is required and a two core cable should be run from the 
WM-CUB to the blind.  
 

Contact Closure  
 

The WM-CUB can be used to provide a control signal to the blinds. In this case a 3 core 
cable is run from the WM-CUB to the blind control box.  
 

 

Mains Blinds wiring:  

 

Terminal 

Mains 

 

Permanent Mains

 

 Relay A Output (Open)

 

 Linked to 4

 

Linked to 3

 

Relay B Output (Close) 

 

Not used 

 

 

 

 
 

RAK8-MB

                   Manual Version 2.1.5 