Raisecom Technology Co., Ltd
19
7. Appendix A Introduction of Cable Making
A.1 E1 interface
z
75ohm adopting DB37 coax adapter:
Suggest using SYV 75-2-2 coax cable, the distance less than 200 meter.
z
120ohm DB37 male connector is defined as following:
DB37 pin
definition
1
st
2
nd
3
rd
4
th
OUT
3, 4
7, 8
11, 12
15, 16
IN
21, 22
25, 26
29, 30
33, 34
Others hang up. Twisted pairs can be jointing on DB37 female connector.
A.2 Cable of Ethernet
Use RJ45 Cat. 5 twisted-pair cable to connect the equipment. The cable shall not be longer
than 100 meters.
Both straight-through and crossover cables will work.
RJ45 line order as following:
Pin
number
1 2 3 4 5 6 7 8
Definition TX+ TX- RX+ Not Used Not Used
RX-
Not Used Not Used
A.3 RS232 cable of data channel
Adopting RJ45 connector, definition of pins as following:
3 ——RXD 232 signal input
6 ——TXD 232 signal output
4, 5 ——GND
others —— hang up (unassigned)
RS232 (RJ45) connect to console of computer (DB9 female connector) line order:
RJ45
DB9F
3
←
— 3
Pin 1
Pin 8