Gazelle ST2028i (A) Hardware Description
4 Cables
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
20
4
Cables
This chapter describes cables for the Gazelle S2028i, including the following sections:
4.1 Grounding cable
4.1.1 Introduction
Connecting the grounding cable properly is an important guarantee to lightning
protection, shock proof, and anti-interference. When installing and using the device,
ensure that the grounding cable is properly connected; otherwise, personnel injury or
equipment damage may be caused.
Connect the grounding cable to the chassis by tightening the grounding screw on the rare
panel. Connect the other side of the cable to the ground.
4.1.2 Appearance
The grounding cable is composed of grounding terminals and the coaxial cable. The
grounding terminal is usually an OT non-insulated terminal. The coaxial cable is a
yellow/green copper soft flame-retardant conducting wire. Figure 4-1and Figure 4-2show the
grounding cable and OT terminal.