Raisecom
Gazelle ST2028i (A) Hardware Description
4 Cables
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
22
Item
Description
Welding technology
The conducting wire and OT terminals adopt solderless
pressed connection.
Error in length of
conducting wire
±5 mm
Table 4-2 lists technical specifications of the OT terminal.
Table 4-2
Technical specifications of the OT terminal
Item
Description
Model
Protective grounding round-pressed terminal (M4)
Compliant standard
JB2436-78
Technical specifications
4.3 soldering lug
Inner radius of soldering lug: 4 mm
Outer radius of soldering lug: ≤ 8 mm
Inner radius of sheath: 2.1 mm
Thickness of soldering lug: ≥ 0.6 mm
Cross-sectional area of the
conducting wire
16–15 AWG (1.25–1.5 mm
2
)
The Gazelle S2028i is delivered without the grounding cable. If required, make the
grounding cable on site according to technical specifications.
The grounding cable cannot be longer than 30 m and should be as short as
possible; otherwise, a grounding bar should be used instead.
4.2 AC power cable
4.2.1 Introduction
The AC power cable supplies 110 V/220 VAC power and 110 V/220 VDC power from the
power souring equipment to the power interface of the Gazelle S2028i, and then transmits
power to the entire device.
The AC power cables of the Gazelle S2028i are different according to local standards.
Table 4-3
AC power supply cable options
Regional standard
Cable
Europe
POL-AC-French mode 3-pin/unstrapped-0.75mm
2
-1.5m/RoHS