INSTALLATION MANUAL
Overview of contents
When you receive your gas fireplace, the following items are included for the establishment of the
combustion chamber:
Contents
Visio 3, 4, 6, 7
Visio 5
1. Logs
qty. 6
qty. 10
2. Secondary burners
qty. 2
qty. 4
3. Filaments
1 bag
1 bag
4. Ember layer: grey/black
3 bags grey/3 bags black
4 bags grey/4 bags black
5. Glass: Sharp/rounded
1 bag sharp/1 bag rounded
1 bag sharp/1 bag rounded
Information plate
All RAIS/ATTIKA gas fireplaces have an information plate which states the fireplace’s gas type, gas
pressure, power, etc. The information plate is laid on top of the gas fireplace on delivery. Position the
information plate on the inside of the inspection hatch so that the heating and plumbing contractor
can access it. Furthermore, you will find an information plate for all Visio Gas models on the back of
the manual.
The production number is positioned in the bottom left of the fireplace.
1
2
3
4
5
Product ID: 0359CS1717
Produced at:
RAIS A/S, Industrivej 20, 9900 Frederikshavn, Danmark
Hergestellt für /Produced for:
ATTIKA FEUER AG, Brunnmatt 16, CH-6330 Cham / RAIS A/S, Industrivej 20, DK-9900 Frederikshavn
CE Label: Rev. 1 07-11-2018
Visio Gas 40/55/90/XX
(VISIO 7)
18
C
11
C
31
C
91
____ /
This appliance must be installed in accordance with the rules in force, and only used in
a suffidebtly ventilated space. Consult instructions before installation and use of this
appliance. Tested and Certified for use on Biopropane.
Efficiency class 1
N
A
T
U
R
A
L
P
R
O
P
A
N
E
GAS CATEGORY and SUPPLY PRESSURE
I2H
I2E
I2E+
I2ELL
I2L I2EK
I2 (43.46 -45.3 MJ/m3
(0°C))
I3+
I3P(30)
I3P(37)
I3P(50)
I3B/P(30)
I3B/P(50)
HEAT
INPUT
(Gross, KW)
BURNER
PRESSURE
(Hot, mbar)
COUNTRY
of DESTINATION
G20 @ 20 mbar
G20 @ 20 mbar
G20↔G25 @
20↔25 mbar
G25 @ 20 mbar
G20/G25.3 @
25 mbar
G30↔G31 @
28↔37 mbar
G31 @ 30 mbar
G31 @ 37 mbar
G31 @ 50 mbar
G30↔G31 @
30 mbar
G30↔G31 @
50 mbar
14.5
14.5
14.5/13.3
12.0
13.3
14.4
11.5
14.4
14.4
14.4
14.4
36
27
36
36
28
27/36
21.6
18.2
18.2/21.5
18.2
18.2
AT, BG, CH, CZ, DK, EE, ES, FI,
GB, GR, HR, IE, IT, LT, LV, NO,
PT, RO, SE, SI, SK, TR
DE, LU, PL, RO
BE, FR
DE
NL
BE, CH, CY, CZ, ES, FR,
GB, GR, IE, IT, LT, PT, SI,
SK, TR
FI, NL, RO
BE, CH, CZ, ES, FR, GB,
GR, HR, IE, IT, LT, NL, PL,
PT, SL, SK, TR
AT, CH, CZ, DE, NL, SK
BE, BG, CY, DK, EE, FI, FR, GB,
GR, HR, HU, IT, LT, MT, NL, NO,
RO, SE, SI, SK, TR
AT, CH, CZ, DE, FR, SK
CITY GAS
G150.1 @ 8 mbar
10.2
3.5
DK, SE
8 - GB
GB
Содержание VISIO 4 Series
Страница 14: ...INSTALLATION MANUAL 5 Position the bottom grate above the burner 14 GB GB ...
Страница 24: ...INSTALLATION MANUAL INSTALLATION MANUAL 1000 1000 150 1000 50 Tunnel models 24 GB GB ...
Страница 70: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE 70 GB GB ...
Страница 71: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE GB 71 GB ...
Страница 72: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE 72 GB GB ...
Страница 73: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE GB 73 GB ...
Страница 74: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE 74 GB GB ...
Страница 75: ...INSTALLATION MANUAL DECLARATION OF CONFORMITY GB 75 GB ...
Страница 76: ...INSTALLATION MANUAL DECLARATION OF CONFORMITY 76 GB GB ...
Страница 77: ...INSTALLATION MANUAL TROUBLESHOOTING TROUBLESHOOTING See the troubleshooting section in the user guide GB 77 GB ...
Страница 99: ...INSTALLATION MANUAL Flue parts GB 99 GB ...
Страница 100: ...INSTALLATION MANUAL 100 GB GB ...
Страница 101: ...INSTALLATION MANUAL GB 101 GB ...
Страница 102: ...INSTALLATION MANUAL 102 GB GB ...
Страница 108: ...INSTALLATION MANUAL 108 GB GB ...