INSTALLATION MANUAL
Gas type
(Liquid petroleum gas - LPG)
G30/G31
I3B/P(30)
G30/G31
I3+
G31
I3P(50)
G31
I3P(37)
G31
I3P(30)
Supply Pressure
mbar
30
30 / 37
50
37
30
Nominal Heat Input
Gross (Hs)
kW
23
22.4
22.4
22.4
19.5
Nominal Heat Input
Net (Hi)
kW
20.5
20
20
20
17.4
Consumption
m³/hr
0.62
0.62 / 0.78
0.78
0.78
0.625
Burner Pressure
(hot)
mbar
27
27 / 36
36
36
28
Injector Marking
120 Centre, 2 x160 Left, 2 x 160 Right
Pilot
G30-ZP2-271 (27.1 inj)
Efficiency Class
1
NOx Class
5
Type
C11 / C31
GB - 65
GB
Содержание VISIO 4 Series
Страница 14: ...INSTALLATION MANUAL 5 Position the bottom grate above the burner 14 GB GB ...
Страница 24: ...INSTALLATION MANUAL INSTALLATION MANUAL 1000 1000 150 1000 50 Tunnel models 24 GB GB ...
Страница 70: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE 70 GB GB ...
Страница 71: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE GB 71 GB ...
Страница 72: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE 72 GB GB ...
Страница 73: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE GB 73 GB ...
Страница 74: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE 74 GB GB ...
Страница 75: ...INSTALLATION MANUAL DECLARATION OF CONFORMITY GB 75 GB ...
Страница 76: ...INSTALLATION MANUAL DECLARATION OF CONFORMITY 76 GB GB ...
Страница 77: ...INSTALLATION MANUAL TROUBLESHOOTING TROUBLESHOOTING See the troubleshooting section in the user guide GB 77 GB ...
Страница 99: ...INSTALLATION MANUAL Flue parts GB 99 GB ...
Страница 100: ...INSTALLATION MANUAL 100 GB GB ...
Страница 101: ...INSTALLATION MANUAL GB 101 GB ...
Страница 102: ...INSTALLATION MANUAL 102 GB GB ...
Страница 108: ...INSTALLATION MANUAL 108 GB GB ...