![RAIS Visio 100 RD Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/rais/visio-100-rd/visio-100-rd_installation-manual_3556300029.webp)
29
GB
RESTRICTORS
Restrictor A
Restrictor B
Restrictor C
Three different restrictor are included for the gas
fireplace. The restrictors are used to create the correct
flow in the balenced flue.
It is important to see and assess from the flame picture
whether the correct restrictor is fitted.
The flames should be blue/yellow at start-up, after
20 minutes the flames should be a clear yellow. If the
desired combustion is not achieved, another restrictor
can be installed.
The restrictors come in three different sizes.
INSTALLATION
RESTRICTORS
Vertical height up to 2 m
Restrictor A
Vertical height up to 2-4 m
Restrictor B
Vertical height up to 4-7 m
Restrictor C
Vertical height up to 7-10 m
Restrictor B
Vertical height up to 10-15 m
Restrictor A
2. Mount the restrictor according to the form, and
then tighten the two screws diagonally.
1. Loosen two of the screws diagonally.
Содержание Visio 100 RD
Страница 1: ...VISIO GAS INSTALLATION MANUAL GB VISIO 100 RD VISIO 100 T...
Страница 2: ...1st edition 10 05 2023...
Страница 59: ......
Страница 60: ...RAIS A S Industrivej 20 DK 9900 Frederikshavn Denmark www rais com...