42
English
RAIS - Manual for RAIS Q-Tee
Installation distance in case of non-combustible wall
Using non insulated smoke pipe, the minimum distance to combustible wall must be
225 mm from smoke pipe.
We recommend a minimum distance to non-combustible material of 50 mm (F) for
cleaning considerations.
It should always be possible to access the access door.
Corner setting 45° fixed socket
Uninsulated flue
Insulated flue
A. Distance to furniture (min.)
650 mm
650 mm
Distance to flammable materials (min.)
B. in front (floor)
300 mm
300 mm
C. to the side (floor)
150 mm
150 mm
D. to the rear (wall)
225 mm
175 mm
E. to the side of the wall
275 mm
225 mm