31
US
Using the stove
Only use wood as fuel as described in the firewood section of this manual.
Adjusting the air control
There are three different positions for air control:
Position 1:
The damper is almost closed meaning that there is
a minimal air intake.
Position 2:
Pull the handle out to the first stop. This position
provides full secondary air intake.
In the event of ordinary combustion the handle is
to be adjusted to the interval between pos. 1 and
2.
When the flames are clear and yellow, the damper
has been adjusted correctly resulting in slow/opti-
mal combustion.
Position 3:
Pull the handle all the way out. The damper is fully
open and provides full primary and secondary air
intake. This position is for the kindling phase and is
not used in connection with normal operation.
REMEMBER THE STOVE IS HOT WHILE IN OPERATION, SO
KEEP CHILDREN, CLOTING, AND FURNITURE AWAY. CON-
TACT WITH A STOVE WHEN BURNING MAY CAUSE SKIN
BURNS.
Warning: Do not fire the stove with the door open!