Chimney

 

The chimney is the driving force which makes the stove function. In order for the stove to 
perform satisfactorily the chimney height must be sufficient to ensure the correct draught 
of 14 to 18 Pa, so as to clear the products of combustion and prevent problems of smoke 
leaking into the room when the stove is lit. 
Note: A chimney height of not less than 4.5 metres, measured vertically from the outlet of 
the stove to the top of the chimney, should be satisfactory. 
Alternatively the calculation procedure given in BS 5854:1980 may be used as the basis 
for deciding whether a particular chimney design will provide sufficient draught. 
Please Note, this appliance has been tested by the manufacturers and works on a 3m 
straight flue. 

The outlet from the chimney should be above the roof of the building in accordance with 
the provisions of the Building Regulations Approved Document J. 

If the installation is into an existing chimney, then it must be sound and have no cracks or 
other faults which may allow fumes into the house. Older properties, especially, may have 
chimney faults or the cross section may be too large i.e. more than 230 x 230mm. 
Remedial action should be taken if required, expert advice should be sought where 
required. 
If the chimney requires lining, then a suitable solid fuel flue liner must be used, in 
accordance with Building Regulations Approved Document J. 

Any existing chimney must be clear of obstruction and should have been swept clean 
immediately before the installation of the stove. If the stove is fitted in place of an open 
fire, then the chimney should be swept one month after installation to clear any soot falls 
which may have occurred due to the difference in combustion between the stove and the 
open fire. 

If there is no existing chimney then either a prefabricated block chimney, in accordance 
with Building Regulations Approved Document J or a twin wall insulated stainless steel 
flue to BS 4543 can be used. These chimneys must be fitted in accordance with the 
manufacturer’s instructions and the Building Regulations. 

A single wall metal fluepipe is suitable for connecting the stove to the chimney but is 
not suitable for using for the complete chimney. The chimney and 
connecting fluepipe must have a minimum diameter of 150mm and it’s 
dimension should be not less than the size of the outlet socket of the stove which is 
150mm. Any bend in the chimney or connecting fluepipe should not exceed 45°. 90° 
bends should not be used. 

Combustible material should not be located where the heat dissipating through the 
walls of fireplaces or flues could ignite it. Therefore when installing the stove in the 
presence of combustible materials due account must be taken of the 
guidance on the separation of combustible material given in Building Regulations Ap­ 
proved Document J and also in these stove instructions.

Содержание GABO

Страница 1: ...AIS PINA RAIS VOLA SOAPSTONE IMPORTANT INFORMATION On first lighting the stove you must be careful not to touch the painted surfaces and it is MOST IMPORTANT that the door is kept slightly ajar in ord...

Страница 2: ...ENGLISH RAIS manual for Rais Gabo Pina Vola Vola Soapstone 2...

Страница 3: ...HT ANGLE SECURE BASE 16 CORNER INSTALLATION 45 16 360 SWIVEL BASE 17 90 SWIVEL BASE 17 INSTALLATION DISTANCE TO NON COMBUSTIBLE WALL 17 FOR THE INSTALLER 18 OPERATING INSTRUCTIONS 19 FUEL 19 DRYING AN...

Страница 4: ...hat you know the stove s production number We therefore recommend that you note down the number in the table below The production number is located in the top of the convection box Warranty Your Rais...

Страница 5: ...245 367 376 245 367 376 245 367 376 245 367 Recommended amount of wood when fuelling kg Based on 2 3 logs of wood approx 25cm 1 5 1 5 1 5 1 5 Min uptake Min draught Pascal 12 12 12 12 Weight kg 140 14...

Страница 6: ...is stoves are convection stoves This means that the stove s back and side panels are not over heated Convection means that there is a circulation of air which ensures that the heat is distributed more...

Страница 7: ...Notice The installation of this heating appliance is governed by the Health and Safety at Work Act 1974 it is the responsibility of the installer to ensure that all requirements of this Act are met du...

Страница 8: ...uel flue liner must be used in accordance with Building Regulations Approved Document J Any existing chimney must be clear of obstruction and should have been swept clean immediately before the instal...

Страница 9: ...quate provision e g easily accessible soot door or doors must be provided for sweeping the chimney and connecting fluepipe You should also familiarise yourself with the draught conditions for chimneys...

Страница 10: ...tion air outlets which may be connected with suit able air ducts to other rooms Building Regulations Approved Document J gives specific guidance on the required permanent ventilation into the room for...

Страница 11: ...ENGLISH RAIS manual for Rais Gabo Pina Vola Vola Soapstone 11...

Страница 12: ...12 If the stove has a turntable then please do the following Lift up the positioning bolt and rotate the stove at 30 intervals When you have reached the desired position release the positioning bolt a...

Страница 13: ...ais Gabo Pina Vola Vola Soapstone 13 Mount the Soapstones as illustrated 1 Remove the screw 1 2 Remove the back panel 2 3 Loosen the nut 3 under the top plate 4 Remove the top plate 4 push the top pla...

Страница 14: ...et 6 6 Push the two flat head screws 7 through the plate 8 7 Put the brass bushes 9 onto the screws between the plate and the Soapstone 5 8 Tighten the flat head screw into the Soapstone bush 10 8 Mou...

Страница 15: ...s Gabo Pina Vola Vola Soapstone 15 10 Refasten the nut under the top plate 3 11 Replace the back panel 2 12 Replace the screw 1 and fasten the back panel 2 13 Carefully place the Soapstone top plate 1...

Страница 16: ...ombustible hearth of a size and construction that is in accordance with the provisions of the current UK Building Regulations Approved Document J If the stove is to be installed on a wooden floor it m...

Страница 17: ...ISH RAIS manual for Rais Gabo Pina Vola Vola Soapstone 17 Installation distance for non combustible walls We recommend a minimum distance to non combustible material of 50mm F for cleaning considerati...

Страница 18: ...ance and appliance connections to the chimney Ensure that the appliance and chimney flue are functioning correctly before finally handing over to the user Read the later parts of this manual for guida...

Страница 19: ...length of the combustion chamber minus 50 60 mm Stoking with wet firewood causes both soot environmental pollution and bad fuel economy Freshly cut wood contains approx 50 70 water and is thoroughly u...

Страница 20: ...in an airy sunny place which is protected against rain the south side of the house is particularly suitable Store the firewood stacks at a hand s breadth apart as this ensures that the air flowing thr...

Страница 21: ...the final gas residues By setting the interval between position 1 and 2 the energy content in the firewood is used optimally as there is oxygen for combustion and for the burning of the pyrolysis gas...

Страница 22: ...sition 1 The damper is closed meaning that there is no air intake Position 2 Push the lever until the first click This position gives full secondary air During normal use the lever is set between posi...

Страница 23: ...plosion The stove gets very hot when in use always wear protective gloves when tending the stove If the stove has not been used for a while follow the steps as if you were using it for the first time...

Страница 24: ...the air damper to the fully open position Tips before firing up Open a door or window close to the wood burning stove If there is storm in the stove coming from the chimney it is advisable to place a...

Страница 25: ...u have a good bed of glowing embers add 2 3 pieces of wood Leave the door ajar until the fire has caught properly then close the door Damper see adjustment of the damper After approximately 5 minutes...

Страница 26: ...he combustion chamber Scrape shovel the ash out and store it in a non flammable container until it has cooled down You can dispose of ash with your normal household waste or recycle on the garden REME...

Страница 27: ...ke out the baffle plate Remove the upper baffle plate by pushing it towards the smoke leader tilting it slightly and then carefully pulling it out Push up the smoke leader lift it from the pins and th...

Страница 28: ...eal chimney draught too large 22 Pa draught control regulator should be installed A stove burning too weakly could be caused by too little firewood too little air supply for the room ventilation dirty...

Страница 29: ...Accessories and spare parts If spare parts other than those recommended by RAIS are used the warranty is voided All replacement spare parts can be purchased from your RAIS distributor stockist See th...

Страница 30: ...ENGLISH RAIS manual for Rais Gabo Pina Vola Vola Soapstone 30...

Страница 31: ...ENGLISH RAIS manual for Rais Gabo Pina Vola Vola Soapstone 31...

Страница 32: ...ENGLISH RAIS manual for Rais Gabo Pina Vola Vola Soapstone 32...

Страница 33: ...ENGLISH RAIS manual for Rais Gabo Pina Vola Vola Soapstone 33...

Страница 34: ...ENGLISH RAIS manual for Rais Gabo Pina Vola Vola Soapstone 34...

Страница 35: ...ENGLISH RAIS manual for Rais Gabo Pina Vola Vola Soapstone 35...

Страница 36: ...nual for Rais Gabo Pina Vola Vola Soapstone 36 U K Distributor Robeys Ltd Riverside Goods Road Belper Derbyshire England DE56 1UU Tel 01773 820940 Fax 01773 820477 E Mail info robeys co uk www robeys...

Отзывы: