REMOVING THE COMBUSTION CHAMBER LINING

The combustion chamber lining protects the body 

of the fireplace insert from the heat of the fire. The 

large differences in temperature can lead to cracks in 

the combustion chamber lining. This will not affect 

the functionality of the fireplace insert. The lining will 

only need be replaced after several years of use when 

it begins to disintegrate. The liner panels are easy to 

place in position in the fireplace insert and can easily 

be replaced by you or your dealer. 

Procedure for removing the combustion chamber 

lining:

1. Remove the flue panel (1) by pushing the front up 

and pulling forward, so that the rear end becomes free 

of the vertical panels. The flue panel can now be 

carefully removed.

2. Remove the base panels (2).

3. Loosen the side panels (3) by 

turning the end of the panel in 

towards the fireplace’s centre. 

Next, carefully remove them.

4.  Remove the rear panels (4) by 

removing the lock in the top of 

the panels. The panels are now 

loose and can be removed.

5.  Panels (5) and (6) are located un-

der the turbo plate and are not nor-

mally removed.

To re-install the combustion chamber lining sections, 

repeat the above procedure in reverse order.

REMOVING THE COMBUSTION CHAMBER LINING

MAX LOAD

The maximum allowable quantity of 

wood is marked with a line on the 

rear panels. In other words, wood 

should not go above this line.

GB

Содержание attika 600 MAX E-2

Страница 1: ...BRUGERVEJLEDNING BEDIENUNGSANLEITUNG USER MANUAL MANUEL D UTILISATEUR BRUKERVEILEDNING BRUKSANVISNING K YTT OHJE GEBRUIKERHANDLEIDING 600 MAX 600 MAX E OSITIV UTLINE EGATIV...

Страница 2: ...Drawing name INDUSTRIVEJ 20 9900 FREDERIKSHAVN DENMARK Phone 45 98 47 90 33 Fax 45 98 47 92 91 E mail info rais dk Homepage www rais dk Corrections D M Y pch 600MAX Heat storage 21 11 2019 A3 11 0801...

Страница 3: ...the handle 14 Removing the combustion chamber lining 15 External air connection Air System 16 Lubricating hinges 18 Fitting the smoke outlet spigot 19 Fitting the top box 20 Fitting the top plate 21...

Страница 4: ...bution plate Seek advice from a building ex pert If the wood burning stove is to be in stalled on a flammable floor national and local regulations must be complied with including for the size of the n...

Страница 5: ...th depth height mm 688 X 440 X 1305 688 X 440 X 1305 Combustion chamber W x D x H mm 544 X 255 X 165 544 X 255 X 165 Min uptake pascal 12 12 Weight kg min depending on the model 223 246 Efficiency 76...

Страница 6: ...A A B B A A B B 688 221 n 1 6 0 438 560 264 5 437 600 MAX 4 Glass 11 0000 6567 341 152 n 9 8 5 1306 1203 115 n 1 3 5 n 1 6 0 79 n 1 1 0 682 440 434 1123 DIMENSIONAL SKETCHES GB...

Страница 7: ...6 A A B B A A B B 221 n 1 6 0 600 MAX 4 Classic 11 0000 6568 688 438 560 437 264 5 n 1 1 0 79 1306 115 1203 n 1 6 0 n 1 3 5 440 434 682 n 9 8 5 152 341 1123 DIMENSIONAL SKETCHES GB...

Страница 8: ...d Follow the installation and operating instruction manual Intermittent operation F Veuillez lire et observer les instructions du mode d emploi Foyer dur e de combustion limit e homologu pour chemin e...

Страница 9: ...il r ggassamleledning og intervalfyring DE Lesen und befolgen Sie die Bedienungsanleitung Zeitbrandfeuerst tte Nur empfohlene Brennstoffe einsetzen UK Fuel types only recommended Follow the installati...

Страница 10: ...o polystyrene blocks 1 which protect the combustion chamber lining in transit These must be removed before starting a fire in the stove The glass is not recyclable The glass must be disposed of along...

Страница 11: ...es only apply to the wood burning stove The final choice of Chimney solution may have a larger safety distance to the flammable material The Chimney solution must always be installed in accordance wit...

Страница 12: ...LAMMABLE MATERIAL 600MAX 600MAX E Three sided The installation distances applicable to the wood burning stove are shown below Bear in mind that the final choice of chimney may have a different safety...

Страница 13: ...12 50 500 1100 321 447 1 1 0 0 770 INSTALLATION DISTANCES Flammable ceiling Safety distances to the flammable ceiling and floor are measured from above and below the door GB...

Страница 14: ...13 1 HEIGHT ADJUSTMENT HEIGHT ADJUSTMENT The stove is equipped with four adjustment screws 1 under the stove Use the adjustment screws to ensure the wood burning stove stands level GB...

Страница 15: ...2 3 2 FITTING CHANGING THE HANDLE The wood burning stove comes with a tem porary handle 1 To remove it undo the screws 2 The new handle 3 can now be fitted to the stove using the screws 2 FITTING THE...

Страница 16: ...ber lining 1 Remove the flue panel 1 by pushing the front up and pulling forward so that the rear end becomes free of the vertical panels The flue panel can now be carefully removed 2 Remove the base...

Страница 17: ...ure the flexible hose 3 on the spigot 1 using the hose clamp 2 Fit the spigot on the stove with the four M5 screws 4 Secure the valve 6 on the base plate using the double sided adhesive gasket 7 and f...

Страница 18: ...e the cover on the rear of the stove and secure the flexible hose 3 on the spigot 1 using the hose clamp 2 Fit the spigot on the stove with the four M5 screws 4 Secure the valve 6 on the wall using su...

Страница 19: ...18 LUBRICATING THE HINGES LUBRICATING THE HINGES LOCK The fireplace must be lubricated regularly using the four moving parts on the lock and hinges see image Use heat resistant oil GB...

Страница 20: ...MOKE OUTLET SPIGOT THE SMOKE OUTLET SPIGOT CAN BE TURNED TWO WAYS YOU CAN CHOOSE EITHER WAY Version A uses the three free holes 1 8 Slits 2 M6 Nuts 3 M6 Washers 4 M6X20mm cylinder screws Version B use...

Страница 21: ...top box place it on the stove and insert the four M5x20mm spacers one in every corner After positioning the top box adjust the intermediary space to 5 mm then tighten the top box with the four M5x10 c...

Страница 22: ...n position and insert the four M5x8 spacers supplied one in every corner Once the top plate is lowered in place over the spacers all four bushings below the top plate must fit over the spacers Adjust...

Страница 23: ...2 Virkningsgrad 76 R ggastemperatur 306 C Afstand til bagv g se opstillingsvejledning Afstand til sidev g se opstillingsvejledning Emissioner iht NS 3058 og eller CEN TS 15883 Partikler efter NS 3058...

Страница 24: ...tilling mod brandbar v g Afstand til sidev g 500 mm normalopstilling mod brandbar v g Emissioner iht NS 3058 og eller CEN TS 15883 Partikler efter NS 3058 g kg t rstof middelv rdi krav 4 Partikler eft...

Страница 25: ...luding units where relevant Energy efficiency 76 Emission of CO 0 09 Emission of OGC 54 mgC Nm3 Emission of NOx 69 mg Nm3 Emission of dust 5 mg Nm3 Test report s No s 300 ELAB 2431 EN covering Rais 60...

Страница 26: ...RAIS A S Industrivej 20 DK 9900 Frederikshavn Denmark www rais dk ATTIKA FEUER AG Brunnmatt 16 CH 6330 Cham Switzerland www attika ch POSITIV OUTLINE NEGATIV...

Отзывы: