85
English
RAIS/
attika
- User manual for Q-BE
note!!
be careful when replacing the smoke converter plate and smoke chikane
Interruption of operation
Smoke spillage around door
could be due to too low draught in the chimney <12pa
•
check whether the flue or chimney is blocked
•
check whether the extraction hood is switched on; if it is, switch it off and open a
window/door in the proximity of the stove for a short while.
Soot on glass
could be caused by the firewood is too wet.
•
make sure that the stove is heated properly when firing up, prior to closing the door
Stove is burning too strong
could be caused by:
•
leak around the door seal
•
chimney draught too large >22 pa, draught control regulator should be installed.
Remove dirt and dust, and mount
the parts in reverse order.
lift off the smoke barrier, pull forward, lower and remove.
Содержание attica Q-BE
Страница 34: ...225...