Chimney 

 
The chimney is the driving force which makes the stove function. In order for the stove to 
perform satisfactorily the chimney height must be sufficient to ensure the correct draught 
of 14 to 18 Pa, so as to clear the products of combustion and prevent problems of smoke 
leaking into the room when the stove is lit. 
Note: A chimney height of not less than 4.5 metres, measured vertically from the outlet of 
the stove to the top of the chimney, should be satisfactory. 
Alternatively the calculation procedure given in BS 5854:1980 may be used as the basis 
for deciding whether a particular chimney design will provide sufficient draught. 
Please Note, this appliance has been tested by the manufacturers and works on a 3m 
straight flue. 
 
The outlet from the chimney should be above the roof of the building in accordance with 
the provisions of the Building Regulations Approved Document J. 
 
If the installation is into an existing chimney, then it must be sound and have no cracks or 
other faults which may allow fumes into the house. Older properties, especially, may have 
chimney faults or the cross section may be too large i.e. more than 230 x 230mm. 
Remedial action should be taken if required, expert advice should be sought where         
required. 
If the chimney requires lining, then a suitable solid fuel flue liner must be used, in  
accordance with Building Regulations Approved Document J. 
 
Any existing chimney must be clear of obstruction and should have been swept clean  
immediately before the installation of the stove. If the stove is fitted in place of an open 
fire, then the chimney should be swept one month after installation to clear any soot falls 
which may have occurred due to the difference in combustion between the stove and the 
open fire. 
 
If there is no existing chimney then either a prefabricated block chimney, in accordance 
with Building Regulations Approved Document J or a twin wall insulated stainless steel 
flue to BS 4543 can be used. These chimneys must be fitted in accordance with the  
manufacturer’s instructions and the Building Regulations. 
 

A single wall metal fluepipe is suitable for connecting the stove to the chimney but is 
not suitable for using for the complete chimney. The chimney and  
connecting fluepipe must have a minimum diameter of 150mm and it’s  
dimension should be not less than the size of the outlet socket of the stove which is 
150mm. Any bend in the chimney or connecting fluepipe should not exceed 45°. 90° 
bends should not be used. 
 
Combustible material should not be located where the heat dissipating through the 
walls of fireplaces or flues could ignite it. Therefore when installing the stove in the 
presence of combustible materials due account must be taken of the guidance on the 
separation of combustible material given in Building Regulations Approved Document 
J and also in these stove instructions. 

Содержание 2:1

Страница 1: ...S 2 1 IMPORTANT INFORMATION On first lighting the stove you must be careful not to touch the painted surfaces and it is MOST IMPORTANT that the door is kept slightly ajar in order for the door seal an...

Страница 2: ...ENGLISH RAIS manual for Rais 2 1 2 April 2014...

Страница 3: ...LATION DISTANCE TO NON COMBUSTIBLE WALL 14 15 INSTALLATION DISTANCE TO COMBUSTIBLE WALL 16 17 GENERAL INSTALLATION 18 FOR THE INSTALLER 19 OPERATING INSTRUCTIONS 20 FUEL 20 DRYING AND STORAGE 21 REGUL...

Страница 4: ...We therefore recommend that you note down the number in the table below The production number is located at the back of the stove at the bottom Warranty Your Rais wood burning stove comes with a 5 yea...

Страница 5: ...nt of wood when fuelling kg Based on 2 3 logs of wood approx 25cm 2 1 Min uptake Min draught Pascal 12 Weight kg 140 Smoke gas mass flow g s 5 1 Smoke gas temperature C 297 Intermittent operation Fuel...

Страница 6: ...hout the entire room The cold air is sucked in at the base of the stove and up through the convection channel which runs along the stove s combustion chamber The heated air comes out at the top of the...

Страница 7: ...The installation of this heating appliance is governed by the Health and Safety at Work Act 1974 it is the responsibility of the installer to ensure that all requirements of this Act are met during th...

Страница 8: ...e liner must be used in accordance with Building Regulations Approved Document J Any existing chimney must be clear of obstruction and should have been swept clean immediately before the installation...

Страница 9: ...ovision e g easily accessible soot door or doors must be provided for sweeping the chimney and connecting fluepipe You should also familiarise yourself with the draught conditions for chimneys with 2...

Страница 10: ...not blocked Building Regulations Approved Document J gives specific guidance on the required permanent ventilation into the room for combustion air of solid fuel appliances The floor structure must b...

Страница 11: ...ments using the levelling bolts in the base Remove the frame and door from the stove Be careful not to damage the glass or paint Leave the protective tape and plastic on the handles during installatio...

Страница 12: ...ENGLISH RAIS manual for Rais 2 1 12 April 2014...

Страница 13: ...ENGLISH RAIS manual for Rais 2 1 13 April 2014...

Страница 14: ...ENGLISH RAIS manual for Rais 2 1 14 April 2014 Insulation ability such as Aqua panel coefficient of thermal conductivity 0 36 W mk or better Please use metal stud...

Страница 15: ...ENGLISH RAIS manual for Rais 2 1 15 April 2014...

Страница 16: ...ENGLISH RAIS manual for Rais 2 1 16 April 2014 The two rows of bricks beneath the stove is limited to a max depth of 75mm...

Страница 17: ...ENGLISH RAIS manual for Rais 2 1 17 April 2014...

Страница 18: ...uld always be installed on a non combustible hearth of a size and construction that is in accordance with the provisions of the current UK Building Regulations Approved Document J If the stove is to b...

Страница 19: ...d appliance connections to the chimney Ensure that the appliance and chimney flue are functioning correctly before finally handing over to the user Read the later parts of this manual for guidance on...

Страница 20: ...f the combustion chamber minus 50 60 mm Stoking with wet firewood causes both soot environmental pollution and bad fuel economy Freshly cut wood contains approx 50 70 water and is thoroughly unsuitabl...

Страница 21: ...chamber and is pre heated through the side channels and then emitted as hot scavenging air onto the glass The hot air rinses the glass and keeps it soot free The tertiary channel which can be seen at...

Страница 22: ...oxi mately 19cm height Adjusting the air damper The damper has 3 settings Position 1 The damper is almost closed meaning that there is a minimal air intake Position 2 Pull push the lever until the fir...

Страница 23: ...on The stove gets very hot when in use always wear protective gloves when tending the stove If the stove has not been used for a while follow the steps as if you were using it for the first time IMPOR...

Страница 24: ...lways opened prior to lighting the stove Tips before firing up Open a door or window close to the wood burning stove If there is storm in the stove coming from the chimney it is advisable to place a s...

Страница 25: ...a good bed of glowing embers add 2 3 pieces of wood Leave the door ajar until the fire has caught properly then close the door Damper see adjustment of the damper After approximately 5 minutes or when...

Страница 26: ...ustion chamber Scrape shovel the ash out and store it in a non flammable container until it has cooled down You can dispose of ash with your normal household waste or recycle on the garden REMEMBER Ne...

Страница 27: ...he sides Remove the baffle plate by lifting it upwards and tilting on it s end The other end is lowered and the baffle plate turned a little Gently take out the baffle plate Now there is a clear view...

Страница 28: ...ney draught too large 22 Pa draught control regulator should be installed A stove burning too weakly could be caused by too little firewood too little air supply for the room ventilation dirty smoke c...

Страница 29: ...parts other than those recommended by RAIS are used the warranty is voided All replacement spare parts can be purchased from your RAIS distributor stockist See the following spare parts diagrams for...

Страница 30: ...ef Quantity Item No Description 1 2 9101401SORT Complete front 2 2 9101090 Door left hinged 2 9101090H Door right hinged 9101090L Door left hinged locked 9101090LH Door right hinged locked 9101032 Too...

Страница 31: ...ENGLISH RAIS manual for Rais 2 1 31 April 2014...

Страница 32: ...ENGLISH RAIS manual for Rais 2 1 32 April 2014...

Страница 33: ...ENGLISH RAIS manual for Rais 2 1 33 April 2014...

Страница 34: ...ENGLISH RAIS manual for Rais 2 1 34 April 2014...

Страница 35: ...ENGLISH RAIS manual for Rais 2 1 35 April 2014...

Страница 36: ...RAIS manual for Rais 2 1 36 April 2014 U K Distributor Robeys Ltd Riverside Goods Road Belper Derbyshire England DE56 1UU Tel 01773 820940 Fax 01773 820477 E Mail info robeys co uk www robeys co uk Ap...

Отзывы: