RainWise Weather Oracle MKIII Скачать руководство пользователя страница 13

  

 

 

 

13

 

 

 

 

 

RainWise Multi Display Users Guide 

2014 Revision 

 

3)

 

Operating the Display 

For a detailed explanation on each parameter display, refer to Section 1.4.   

3.1)

 

Selecting Display Parameters 

Pressing the button below a display will cycle through the available display options.  The LED 
next to the display will indicate the current selection.  The scroll mode will cycle through these 
selections automatically.  Refer to Section 2.4 to set auto scroll.  

3.2)

 

Turning Displays On and Off 

Displays may be turned on or off independently. 

 

Enter the Setup mode by pressing 

MAX

 then 

SELECT

.  The MAX and MIN LEDs 

should be flashing.   

 

Press 

BRIGHTNESS

.   

 

Each display will show either “on” or “oFF”. 

 

To change a display’s status, press the button below the desired display (for example, 
“TIME”.)  This will toggle the status.   

 

Press 

SELECT

 when done.   

 

Press 

SELECT

 again to exit the setup mode.   

 

3.3)

 

Displaying Minimums and Maximums 

 
To display a maximum value, press 

MAX,

 then press the button below the desired display. The 

maximum value will be displayed along with the date and time of occurrence. The “min” or 
“max” of the current selection will be displayed. Ensure that the desired selection is being 
displayed before doing the max/min sequence. If the window is scrolling, stop it by pressing the 
button below the display before pressing 

MAX. 

 

3.4)

 

Resetting Minimums and Maximums 

 
Minimum values are displayed in the same manner as the maximums.  Maximums and 
Minimums can be reset by pressing 

SELECT

 while a max or min is being displayed. The new 

value will flash to indicate that it has been reset. 
 
 
 

Содержание Weather Oracle MKIII

Страница 1: ...Weather Oracle MKIII MKIII LR User s Guide Rev Date 7 08 14...

Страница 2: ...pyright 2014 by RainWise Inc All rights reserved No part of this work may be reproduced in any form except by written permission of the publisher All rights of translation are reserved RainWise Multi...

Страница 3: ...ure 10 2 22 Wind Speed 10 2 23 Rainfall 10 2 24 Barometer 11 2 3 Brightness 11 2 4 Automatic Toggling of Displays 11 2 5 Fine Tuning Temperatures 12 2 6 Setting Temperature Characters 12 3 Operating t...

Страница 4: ...4 RainWise Multi Display Users Guide 2014 Revision 3 71 Lock Display 14 3 72 Unlock Display 15 4 Diagnostic Mode 15 4 1 Factory Reset 16 5 Product Support 16 5 1 Contact Information 17 5 2 Warranty 17...

Страница 5: ...e power source 9 volts DC 500mA to the radio transmitter Only use the power source provided with this multi display oracle since it is different from the standard oracle display Do not attempt to use...

Страница 6: ...option for battery backup There are slots in the back for 5 AAA alkaline batteries in all wooden frame units Metal Framed displays do not have battery backup option Refer to the diagram on the back of...

Страница 7: ...ernal temperature sensor will record the exact temperature at the mounting location For example if the unit is mounted on an exterior wall the reading will be affected by the temperature of the wall w...

Страница 8: ...Keep pressing SELECT to Exit Make a parameter toggle SELECT parameter button Lock display MAX SELECT HUMIDITY Press HUMIDITY button to toggle to Loc SELECT twice when done Unlock display HUMIDITY and...

Страница 9: ...ld be flashing Press the TIME button press on the word TIME The current time will appear Press the MAX button once Use the MIN and MAX buttons to select 12 hour or 24 hour format Press SELECT to accep...

Страница 10: ...s SELECT when done 2 22 Wind Speed Be sure you re in the setup mode The max and min LED s should be flashing Press WIND SPEED press on the words WIND SPEED The wind speed display will show U 0 U 1 U 2...

Страница 11: ...t OPTIONAL To display the actual offset value press MAX and MIN at the same time You can set this back to zero by pressing the SELECT key You must be holding down both MAX and MIN when you do this Pre...

Страница 12: ...rrect Press MAX to increase the offset and MIN to decrease it Press MAX and MIN at the same time to display the actual offset value You can set this back to zero by pressing the SELECT key You must be...

Страница 13: ...nge a display s status press the button below the desired display for example TIME This will toggle the status Press SELECT when done Press SELECT again to exit the setup mode 3 3 Displaying Minimums...

Страница 14: ...LECT The MAX and MIN LEDs should be flashing Press RAINFALL The current units will be either U 0 or U 1 Press SELECT Adjust the CUR counter using the MAX and MIN buttons Press SELECT when done Press S...

Страница 15: ...ults Enter the diagnostic mode Press then BE SURE TO RECORD THE FOLLOWING VALUES BEFORE RESETTING YOUR DEVICE HUMIDITY shows the software versions of the display and sensor unit The two digits on the...

Страница 16: ...nce the button has been pressed the unit will reset The EEPROM memory is tested this may take a few seconds If the process is halted and the time display shows bad contact the RainWise Service Departm...

Страница 17: ...Wise Inc will not pay for warranty service performed by a non authorized repair service and will not reimburse the consumer for damage resulting from warranty service performed by a non authorized rep...

Отзывы: