*
Operational Specifications
Working Pressure
40 psi _ 100 psi (275 kPa _ 689 kPa)
Operating Temperatures
50°F _ 100°F (10°C _ 38°C)
pH Range
2 _ 11
Maximum TDS Level
1400 parts per million (PPM)
Maximum Turbidity Influent Level
11 NTU (nephelometric turbidity units)
Maximum Hardness Level
5 grains per gallon (85ppm)
Capacity for VOC Reduction
225 gallons (850 liters)
Approximate Flow Rate @ 60psi:
0.94 gpm
Data Chart
Additional Specifications
• The inlet water should be free from iron, manganese, and sulfur.
• This system has been tested for the treatment of water containing
pentavalent arsenic (also known as AS (V), As (+5), or arsenate) at
concentrations of 0.30 mg/L or less. This system reduces pentavalent
arsenic, but may not remove other forms of arsenic. This system is to be
used on water containing a detectable free chlorine residual or on water
supplies that have been demonstrated to contain only pentavalent
arsenic. Treatment with chloramine (combined chlorine) is not suffi-
cient to ensure complete conversion of trivalent arsenic to pentavalent
arsenic. Please see the Arsenic Facts section of the performance data
sheets for further information.
• Do not use this product with water that is microbiologically unsafe or
of unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on disinfected
waters that may contain filterable cysts.
• This system must be installed in accordance with all applicable state
and local laws and regulations.
• This system must be installed in an area not affected by extreme heat,
cold or the elements. The selected installation area must be adequate for
easy service of all parts.
• This system is designed to treat cold water only. The installation must
be on a cold water supply.
5
!
Important Note:
If the hardness is greater than 5 grains, the
system will still perform properly, but the
longevity of the membrane may be affected.
The efficiency and recovery ratings are verified by
testing in accordance with NSF/ANSI Standard 58.
Efficiency rating means the percentage of the
influent water to the system that is available to
the user as reverse osmosis treated water under
operating conditions that approximate typical
daily usage.
Recovery rating means the percentage of the
influent water to the membrane portion of the
system that is available to the user as reverse
osmosis treated water when the system is oper-
ated without a storage tank or when the storage
tank is bypassed.
Model
Faucet Model
Daily
Production Rates
Efficiency
Rating
*
Recovery
Rating*
ULTREFINER II -FMV
BNFP
16.02 gpd / (60.64 L/day)
17.54%
37.23%
BNFV
CHFP
CHFV
Содержание Ultrefiner II
Страница 47: ...47 NOTAS...