20
20
PERFORMANCE DATA SHEET - page 2 of 3
Ultrefiner II - FMV
PREMIUM DRINKING WATER SYSTEM
CONTAMINANT
INFLUENT CHALLENGE
CONCENTRATION
mg/L
MAXIMUM PERMISSIBLE
PRODUCT WATER
CONCENTRATION mg/L
USEPA
MCL (MG/L)
ALACHLOR
0.050
0.001
0.002
ATRAZINE
0.100
0.003
0.003
BENZENE
0.081
0.001
0.005
CARBOFURAN
0.190
0.001
0.04
CARBON TETRACHLORIDE
0.078
0.0018
0.005
CHLOROBENZENE
0.077
0.001
0.1
CHLOROPICRIN
0.015
0.0002
--------
2,4-D
0.110
0.0017
0.07
DIBROMOCHLOROPROPANE (DBCP)
0.052
0.00002
0.0002
O-DICHLOROBENZENE
0.080
0.001
0.60
P-DICHLOROBENZENE
0.040
0.001
0.075
1,2-DICHLOROETHANE
0.088
0.0048
0.005
1,1-DICHLOROETHYLENE
0.083
0.001
0.007
CIS- 1,2-DICHLOROETHYLENE
0.170
0.0005
0.07
TRANS- 1,2-DICHLOROETHYLENE
0.086
0.001
0.10
1,2-DICHLOROPROPANE
0.080
0.001
0.005
CIS-1,3-DICHLOROPROPYLENE
0.079
0.001
--------
DINOSEB
0.170
0.0002
0.007
ENDRIN
0.053
0.00059
0.002
ETHYLBENZENE
0.088
0.001
0.70
ETHYLENE DIBROMIDE (EDB)
0.044
0.00002
0.00005
HALOACENTONITRILES (HAN):
BROMOCHLOROACETONITRILE
0.022
0.0005
----------
DIBROMOACETONITRILE
0.024
0.0006
----------
DICHLOROACETONITRILE
0.0096
0.0002
----------
TRICHLOROACETONITRILE
0.015
0.0003
----------
HALOKETONES (HK):
1,1-DICHLORO-2-PROPANONE
0.0072
0.0001
--------
1,1,1-TRICHLORO-2-PROPANE
0.0082
0.0003
--------
HEPTACHLOR
0.025
0.00001
0.0004
HEPTACHLOR EPOXIDE
0.011
0.0002
0.0002
HEXACHLOROBUTADIENE
0.044
0.001
--------
HEXACHLOROCYCLOPENTADIENE
0.060
0.000002
0.05
LINDANE
0.055
0.00001
0.0002
METHOXYCHLOR
0.050
0.0001
0.04
PENTACHLOROPHENOL
0.096
0.001
0.001
SIMAZINE
0.120
0.004
0.004
STYRENE
0.150
0.0005
0.10
1,1,2,2-TETRACHLOROETHANE
0.081
0.001
--------
TETRACHLOROETHYLENE
0.081
0.001
0.005
TOLUENE
0.078
0.001
1.00
TRIBROMOACETIC ACID
0.042
0.001
--------
2,4,5-TP (SILVEX)
0.270
0.0016
0.05
1,2,4-TRICHLOROBENZENE
0.160
0.0005
0.07
1,1,1-TRICHLOROETHANE
0.084
0.0046
0.20
1,1,2-TRICHLORETHANE
0.150
0.0005
0.005
TRICHLOROETHYLENE
0.180
0.001
0.005
TRIHALOMETHANES
0.300
0.015
0.08
XYLENES (TOTAL)
0.070
0.001
10
NSF/ANSI STANDARD 53 TEST CONDITION: 60 ± 3 psi, pH 7.5 ± 0.5, 68 ± 5 ºF
1. THESE SYSTEMS HAVE BEEN TESTED FOR THE TREATMENT OF WATER
CONTAINING PENTAVALENT ARSENIC (ALSO KNOWN AS As(V), As(+5),
OR ARSENATE) AT CONCENTRATIONS OF 0.30 mg/L OR LESS. THIS SYS-
TEM REDUCED PENTAVALENT ARSENIC, BUT MAY NOT REMOVE OTHER
FORMS OF ARSENIC. THIS SYSTEM IS TO BE USED ON WATER SUPPLIES
CONTAINING A DETECTABLE FREE CHLORINE RESIDUAL AT THE SYSTEM
INLET OR ON WATER SUPPLIES THAT HAVE BEEN DEMONSTRATED TO
CONTAIN ONLY PENTAVALENT ARSENIC. TREATMENT WITH CHLORAMINE
(COMBINED CHLORINE) IS NOT SUFFICIENT TO ENSURE COMPLETE CON-
VERSION OF TRIVALENT ARSENIC TO PENTAVALENT ARSENIC. PLEASE
SEE THE ARSENIC FACT SECTION OF THE PERFORMANCE DATA SHEET
FOR FURTHER INFORMATION.
2. THE ULTREFINER II IS ACCEPTABLE FOR TREATMENT OF INFLUENT
CONCENTRATIONS OF NO MORE THAN 27 mg/L NITRATE AND 3 mg/L
NITRITE IN COMBINATION MEASURED AS “N” AND IS CERTIFIED FOR
NITRATE/NITRITE REDUCTION ONLY FOR WATER SUPPLIES WITH A PRES-
SURE OF 280 kPa (40 psig) OR GREATER. ADDITIONAL TREATMENT OR
INDIVIDUAL DESIGN SHALL BE REQUIRED FOR HIGHER INFLUENT LEV-
ELS. IF YOU ARE RELYING ON THE ULTREFINER II FOR NITRATE REDUC-
TION, WE RECOMMEND TESTING YOUR WATER PERIODICALLY (2 TIMES A
YEAR MINIMUM) WITH A NITRATE TEST KIT (SUPPLIED) TO ENSURE THAT
THE SYSTEM IS PERFORMING PROPERLY. ADDITIONAL NITRATE TEST
KITS (PART NUMBER 12061) CAN BE PURCHASED FROM YOUR LOCAL
RAINSOFT DEALER.
3. EFFICIENCY RATING MEANS THE PERCENTAGE OF INFLUENT WATER TO
THE SYSTEM THAT IS AVAILABLE TO THE USER AS REVERSE OSMOSIS
TREATED WATER UNDER OPERATING CONDITIONS THAT APPROXIMATE
TYPICAL DAILY USAGE.
4. RECOVERY RATING MEANS THE PERCENTAGE OF THE INFLUENT WATER
TO THE MEMBRANE PORTION OF THE SYSTEM THAT IS AVAILABLE TO
THE USER AS REVERSE OSMOSIS TREATED WATER WHEN THE SYSTEM IS
OPERATED WITHOUT A STORAGE TANK OR WHEN THE STORAGE TANK IS
BYPASSED.
5. REDUCTIONS SHOWN ARE FOR VOLATILE ORGANIC CHEMICALS/COM-
POUNDS (VOC) AS PER NSF TABLES. CHLOROFORM WAS USED AS A
SURROGATE FOR VOC CLAIMS REDUCTION. THE ACTUAL REDUCTION
RATE OF CHLOROFORM WAS 99.7% AS TESTED BY NSF INTERNATIONAL
AT 200% CAPACITY (I.E 450 GALLONS) PER NSF/ANSI 53 STANDARD.
For purchases made in the State of Iowa: This form must be signed and dated by the buyer and seller prior
to the consummation of this sale. The seller for a minimum of two years should retain this form on file.
Buyer _________________________________
Seller ___________________________________
Name _________________________________
Name ___________________________________
Address _______________________________
Address _________________________________
City _________ State ___ Zip _____________
City _______ State ____ Zip _______________
Signature ___________
Date ____________
Signature _________
Date ______________
VOC, Standard 53 Reduction Claims
5
Содержание Ultrefiner II
Страница 47: ...47 NOTAS...