RainSoft UF Series Скачать руководство пользователя страница 8

How to Change the System Components

1. Turn off the cold water supply.

2. Open the R.O. faucet and close the storage tank valve.

3. Remove the R.O. unit from the hanger and place it over a drip pan (to

prevent water spillage).

4. To replace the pre-filter, use the filter wrench (not supplied) to 

unscrew the pre-filter housing from the cap (see figures 6 and 7). 
Replace the pre-filter and reassemble.

To change the membrane cartridge, use the filter wrench (not 
supplied) to unscrew the membrane housing from the control head 
(see figures 6 and 7). Replace the membrane cartridge and 
reassemble.

To replace the post-filter, use the filter wrench (not supplied) to 
unscrew the post-filter housing from the cap (see figures 6 and 7). 
Replace the post-filter and reassemble.

To replace both filters and the membrane cartridge, use the filter
wrench (not supplied) to unscrew all the housings from the caps. 
Follow the above steps in consecutive order.

RainSoft Replacement Parts

The following RainSoft replacement parts are available through your
local RainSoft Dealer:

If you are unable to order replacement parts from your local RainSoft
Dealer, please contact RainSoft at 1-800-860-7638 for assistance.

8

FILTER WRENCH

PRE-FILTER

MEMBRANE

POST FILTER

!

Important Note: This Reverse Osmosis System
contains replaceable components critical to
the efficiency of the system. Replacement of
the Reverse Osmosis components should be
one of identical specifications, as defined by
the manufacturer, to assure the same effi-
ciency and contaminant reduction perform-
ance.

Figure 6

Figure 7

Helpful Tips: To avoid contamination, we
recommend the use of sterile gloves while
changing the system components.

When changing the membrane cart- ridge,
verify that the rubber brine seal and O-rings
are secure and in place. Always lubricate the o-
rings with a non-petroleum based lubricant to
ensure the longevity of the o-rings. Never

over-tighten the housing to the cap _ HAND
TIGHT ONLY!

Model

Pre-filter

Membrane

Cartridge

Post-filter

UF22T-CB

18557

12448

18557

UF50N-CBVOC

18557

18644

18773

!

Important Note: It is important to main-
tain the quality of your system by using
only genuine RainSoft replacement
filters and cartridges. Other “made-to-
fit” alternative filters and cartridges
claim to perform the same duties as the
original RainSoft parts, but these items
are not approved for use in your system!
“Made-to-fit” alternative filters and
cartridges will increase the probability
of leaks, putting your entire system at
risk!

When “made-to-fit” alternative  filters
and cartridges are placed into your
RainSoft Reverse Osmosis System, the
product warranty will become null and
void and the system will lose the WQA
certification. To guarantee proper opera-
tion and certification of your RainSoft
Reverse Osmosis System, please use
genuine RainSoft parts.

Description

Part Number

Slim Line Spanner Wrench 

13203

Содержание UF Series

Страница 1: ...08 UF SERIES REVERSE OSMOSIS DRINKING WATER SYSTEM The UF series is tested and certified by NSF International against NSF ANSI standard 58 for the reduction of claims specified on the performance dat...

Страница 2: ...s Required for Installation 4 Installation Instructions 5 System Start Up 6 Routine System Maintenance 6 Periodic System Maintenance 7 RainSoft Replacement Part Numbers 7 How to Change the System Comp...

Страница 3: ...the Reverse Osmosis process your water supply will flow over the surface of a semi permeable membrane to a less concentrated solution The treated water is then stored in the storage tank The tank is p...

Страница 4: ...t be on a cold water supply Data Chart Items Required for Installation Tools Drill drill bits tube cutter screwdrivers adjustable wrench and vinyl gloves Parts RainSoft faucet inlet shut off valve 1 4...

Страница 5: ...o connect the storage tank shut off valve to the tank port on the control head see figure 2 Additional tubing may be required 6 Connect the Drain Outlet Use 1 4 inch tubing not supplied to connect the...

Страница 6: ...into small drips Close the R O faucet and rotate the drain barrel 90o to the fast flush position see figure 3 The sound of rushing water should now be heard Allow the system to fast flush for 5 to 7...

Страница 7: ...arrange this testing for a nominal fee System Components Pre filter The pre filter see figure 5 removes particles and sediment as small as 5 microns in size from the water supply The pre filter requir...

Страница 8: ...the system Replacement of the Reverse Osmosis components should be one of identical specifications as defined by the manufacturer to assure the same effi ciency and contaminant reduction perform ance...

Страница 9: ...er 2 Film on Water or Cloudy Water 2 Faulty valve 2 Replace or repair the valve 3 The water supply is blocked 3 Clear the blockage 4 The membrane cartridge is fouled 4 Replace the membrane cartridge 5...

Страница 10: ...7 6 1 18557 Carbon Block Filter with Sediment Sleeve 7 1 12448 18644 High Flow Unibody Element TFC UF22T CB UF22N CB Element Membrane TFC 50 GPD UF50T CBVOC UF50N CBVOC 8 1 18557 18773 Carbon Block Fi...

Страница 11: ...warranty does not include labor charges and does not cover installation transportation or any other claims or torts Some states do not allow the exclusion or limitation of incidental or consequential...

Страница 12: ...12 Installer Specification Sheet Dealer Name Phone Number Installation Number Installation Date Model Number Serial Number See Label Hardness Line Pressure psi Hardness Chlorine pH Inlet TDS...

Страница 13: ...NOTES 13...

Страница 14: ...14 NOTES...

Страница 15: ...15 NOTES...

Страница 16: ...ision of Aquion Water Treatment Products 2080 East Lunt Avenue Elk Grove Village Illinois 60007 Main Switchboard 1 847 437 9400 Customer Service 1 800 860 7638 www rainsoft com 2006 RAINSOFT DIVISION...

Отзывы: