System Start Up

1. Turn on the Water Supply

• Allow the system to start filling with water.

2. Fast Flush the System

• Open the R.O. faucet and position the drain barrel in the fast flush

position (see figure 3).

3. Reposition the Drain Barrel

• Once the air has been purged from the system, position the drain

barrel in 1 of the 2 service positions (see figure 4). The storage tank
will continue to fill with water.

4. Check for Leaks

• If a leak is present, make the necessary repairs.

5. Fill the System

• When the water stops flowing to the drain, the system should be

fully pressurized and the storage tank should be filled with water.

6. Drain the Storage Tank

• Open the R.O. faucet and drain all the water from the storage tank.   

7. Complete the Installation

• If a 24 hour-flush pre-installation is not performed by your local 

dealer, it is important to open the faucet, let the system drip for 24
hours  first.

• After the 24 hour water flush , close the R.O. faucet and allow the 

storage tank to fill with water. When the storage tank is full, the 
system will be ready for operation.

Routine System Maintenance

The storage tank should be drained and the system should be fast flushed
1 to 2 times per week.
To drain the storage tank, open the R.O. faucet and let the water run until
the flow turns into small drips. Close the R.O. faucet and rotate the drain
barrel 90o to the fast flush position(see figure 3).The sound of rushing
water should now be heard. Allow the system to fast flush for 5 to 7
minutes and then rotate the drain barrel to position#2 (see figure4).

!

Important Note: Do not attempt to reset or
remove the drain barrel screw. The drain barrel
screw is preset by your RainSoft Dealer and
should only be adjusted by a qualified
RainSoft Technician. Tampering with this part
may result in poor system performance, leaks
in the equipment and/or personal injury.

!

Important Note: It is common to experience
cloudy water, cloudy or hazy ice cubes and/or
air bubbles when the system is new or after the
filters/ cartridges have been changed.

FAST FLUSH
POSITION

DRAIN BARREL
SERVICE
POSITION 1

DRAIN BARREL
SERVICE
POSITION 2

Figure 3

Figure 4

Helpful Tips: Maintaining a fresh water supply
in the storage tank will promote better opera-
tion of the membrane cartridge.

The next time you drain the storage tank,
reverse the rotation of the drain barrel.

When you go on vacation, close the cold water
inlet valve. When you return from vacation,
open the cold water inlet valve, drain the
storage tank and fast flush the system.

!

Important Note: Air trapped in the system will
purge during this procedure.

!

Important Note: This procedure will flush any
remaining residue from the storage tank.

!

Important Note: The 24 hour flush will ensure
the proper rinsing of the R.O. Membrane. 

Содержание UF Series

Страница 1: ...08 UF SERIES REVERSE OSMOSIS DRINKING WATER SYSTEM The UF series is tested and certified by NSF International against NSF ANSI standard 58 for the reduction of claims specified on the performance dat...

Страница 2: ...s Required for Installation 4 Installation Instructions 5 System Start Up 6 Routine System Maintenance 6 Periodic System Maintenance 7 RainSoft Replacement Part Numbers 7 How to Change the System Comp...

Страница 3: ...the Reverse Osmosis process your water supply will flow over the surface of a semi permeable membrane to a less concentrated solution The treated water is then stored in the storage tank The tank is p...

Страница 4: ...t be on a cold water supply Data Chart Items Required for Installation Tools Drill drill bits tube cutter screwdrivers adjustable wrench and vinyl gloves Parts RainSoft faucet inlet shut off valve 1 4...

Страница 5: ...o connect the storage tank shut off valve to the tank port on the control head see figure 2 Additional tubing may be required 6 Connect the Drain Outlet Use 1 4 inch tubing not supplied to connect the...

Страница 6: ...into small drips Close the R O faucet and rotate the drain barrel 90o to the fast flush position see figure 3 The sound of rushing water should now be heard Allow the system to fast flush for 5 to 7...

Страница 7: ...arrange this testing for a nominal fee System Components Pre filter The pre filter see figure 5 removes particles and sediment as small as 5 microns in size from the water supply The pre filter requir...

Страница 8: ...the system Replacement of the Reverse Osmosis components should be one of identical specifications as defined by the manufacturer to assure the same effi ciency and contaminant reduction perform ance...

Страница 9: ...er 2 Film on Water or Cloudy Water 2 Faulty valve 2 Replace or repair the valve 3 The water supply is blocked 3 Clear the blockage 4 The membrane cartridge is fouled 4 Replace the membrane cartridge 5...

Страница 10: ...7 6 1 18557 Carbon Block Filter with Sediment Sleeve 7 1 12448 18644 High Flow Unibody Element TFC UF22T CB UF22N CB Element Membrane TFC 50 GPD UF50T CBVOC UF50N CBVOC 8 1 18557 18773 Carbon Block Fi...

Страница 11: ...warranty does not include labor charges and does not cover installation transportation or any other claims or torts Some states do not allow the exclusion or limitation of incidental or consequential...

Страница 12: ...12 Installer Specification Sheet Dealer Name Phone Number Installation Number Installation Date Model Number Serial Number See Label Hardness Line Pressure psi Hardness Chlorine pH Inlet TDS...

Страница 13: ...NOTES 13...

Страница 14: ...14 NOTES...

Страница 15: ...15 NOTES...

Страница 16: ...ision of Aquion Water Treatment Products 2080 East Lunt Avenue Elk Grove Village Illinois 60007 Main Switchboard 1 847 437 9400 Customer Service 1 800 860 7638 www rainsoft com 2006 RAINSOFT DIVISION...

Отзывы: