RainSoft UF Series Скачать руководство пользователя страница 5

Installation Instructions

1. Install the Filters and Membrane Cartridge

• Wearing sterile gloves, remove the two filters and membrane

cartridge from the sterile packaging and place them in the appro-
priate housings (see figure 2).

2. Mount the System

• Use screws (not supplied) to secure the mounting bracket 

(supplied) to the desired location.

3. Install the Faucet (Not Supplied)

• Select a location for the faucet (not supplied) to be mounted.

• Drill a hole according to the manufacturer’s recommendations.

Once the hole has been drilled, mount the faucet.

• Use 3/8 inch tubing (not supplied) to connect the faucet to the

system outlet (see figure 2).

4. Install the Inlet Shut Off Valve (Not Supplied)

• Turn off the cold water supply and open the cold water faucet to

relieve any line pressure.

• Install an inlet shut off valve (not supplied) between the existing

shut off valve and the kitchen faucet, in a way that conforms to
state and local plumbing codes.

• Use 3/8 inch tubing (not supplied) to connect the inlet shut off

valve to the system inlet (see figure 2).

5. Install the Storage Tank

• Select a location for the storage tank. The storage tank can be 

installed vertically or horizontally.

• Verify that the o-ring on the storage tank is in place.

• Install the shut off valve (supplied) onto the storage tank (see 

figure 2). The shut off valve must be in the open position.

• Use the 3/8 inch x 4 foot tubing (supplied) to connect the storage

tank shut off valve to the tank port on the control head (see 
figure 2). Additional tubing may be required

6. Connect the Drain Outlet

• Use 1/4 inch tubing (not supplied) to connect the drain outlet to

the appropriate drain connection (see figure 2).

7. Secure the Connections

• Attach the red locking clips (supplied) to the connection fittings.

5

Helpful Tip: Be careful not to contaminate the
filters and membrane cartridge by touching non-
sterile objects.

Helpful Tip: The proper drill bit should be selected
according to the type of material at the desired
installation location.

INLET 

OUTLET

DRAIN OUTLET

STORAGE TANK

  TANK PORT

SHUT OFF VALVE

PRE-FILTER

MEMBRANE

POST FILTER

Helpful Tip: If the desired installation location is
in the basement, the storage tank can be
mounted in between the floor joists. The closer
the storage tank is to the faucet, the greater the
flow of water.

The storage tank can be installed vertically or
horizontally.

Helpful Tip: To secure the connection, press the
tubing in firmly.

!

Important Note: The drain connection must
conform to state and local plumbing codes.

If the system is mounted under a kitchen sink, an
air gap faucet will be required. If the system is
mounted in a different location, a non-air gap
faucet will be required, along with a separate air
gap device on the drain line (see figures below--
Air Gap-floor drain, Air Gap-Mr.Drain).

Figure 2

1/2" DRAIN LINE

FLOOR DRAIN

AIR GAP

Helpful Tip: Additional tubing may be required.

!

Important Note: The inlet shut off valve must
have a 3/8 inch connection.

AIR GAP - floor drain

AIR GAP - Mr. Drain

Содержание UF Series

Страница 1: ...08 UF SERIES REVERSE OSMOSIS DRINKING WATER SYSTEM The UF series is tested and certified by NSF International against NSF ANSI standard 58 for the reduction of claims specified on the performance dat...

Страница 2: ...s Required for Installation 4 Installation Instructions 5 System Start Up 6 Routine System Maintenance 6 Periodic System Maintenance 7 RainSoft Replacement Part Numbers 7 How to Change the System Comp...

Страница 3: ...the Reverse Osmosis process your water supply will flow over the surface of a semi permeable membrane to a less concentrated solution The treated water is then stored in the storage tank The tank is p...

Страница 4: ...t be on a cold water supply Data Chart Items Required for Installation Tools Drill drill bits tube cutter screwdrivers adjustable wrench and vinyl gloves Parts RainSoft faucet inlet shut off valve 1 4...

Страница 5: ...o connect the storage tank shut off valve to the tank port on the control head see figure 2 Additional tubing may be required 6 Connect the Drain Outlet Use 1 4 inch tubing not supplied to connect the...

Страница 6: ...into small drips Close the R O faucet and rotate the drain barrel 90o to the fast flush position see figure 3 The sound of rushing water should now be heard Allow the system to fast flush for 5 to 7...

Страница 7: ...arrange this testing for a nominal fee System Components Pre filter The pre filter see figure 5 removes particles and sediment as small as 5 microns in size from the water supply The pre filter requir...

Страница 8: ...the system Replacement of the Reverse Osmosis components should be one of identical specifications as defined by the manufacturer to assure the same effi ciency and contaminant reduction perform ance...

Страница 9: ...er 2 Film on Water or Cloudy Water 2 Faulty valve 2 Replace or repair the valve 3 The water supply is blocked 3 Clear the blockage 4 The membrane cartridge is fouled 4 Replace the membrane cartridge 5...

Страница 10: ...7 6 1 18557 Carbon Block Filter with Sediment Sleeve 7 1 12448 18644 High Flow Unibody Element TFC UF22T CB UF22N CB Element Membrane TFC 50 GPD UF50T CBVOC UF50N CBVOC 8 1 18557 18773 Carbon Block Fi...

Страница 11: ...warranty does not include labor charges and does not cover installation transportation or any other claims or torts Some states do not allow the exclusion or limitation of incidental or consequential...

Страница 12: ...12 Installer Specification Sheet Dealer Name Phone Number Installation Number Installation Date Model Number Serial Number See Label Hardness Line Pressure psi Hardness Chlorine pH Inlet TDS...

Страница 13: ...NOTES 13...

Страница 14: ...14 NOTES...

Страница 15: ...15 NOTES...

Страница 16: ...ision of Aquion Water Treatment Products 2080 East Lunt Avenue Elk Grove Village Illinois 60007 Main Switchboard 1 847 437 9400 Customer Service 1 800 860 7638 www rainsoft com 2006 RAINSOFT DIVISION...

Отзывы: